Redundancy (Switches 8200zl)

Displaying Management Information

Standby Management Module Commands

The standby management module, by design, has very little console capability. You can use three commands—show flash, show version, and show redundancy. The show redundancy command displays when a management module is in standby mode.

Show Redundancy

Use the show redundancy command to display redundancy status on the standby module, as shown in Figure 15-19.It displays the flash image last booted from, even if the boot set-defaultcommand has been set to change the flash booted from on the next boot.

Standby Console> show redundancy

Settings

--------

Mgmt Redundancy : Enabled

 

Statistics

 

 

The active management module was last booted from

 

 

 

secondary flash. The standby management module

 

----------

 

 

was last booted from primary flash.

 

Failovers

: 1

 

 

 

 

 

 

 

Last Failover : Mon Sep 26 09:50:40 2005

 

 

 

 

 

 

Slot Module Description

Status

SW Version Boot

 

Image

 

---- ----------------------------------------

--------

---------- ----------

1

ProCurve J9092A Management Module 8200zl

Active

K.12.XX

Secondary

2

ProCurve J9092A Management Module 8200zl

Standby

K.12.XX

Primary

1ProCurve J9093A F1 Fabric Module 8200zl Enabled

2ProCurve J9093A F2 Fabric Module 8200zl Enabled

Figure 15-19. Example of Show Redundancy Command for Standby Module

Show Flash

You can display the flash information on the standby module, as shown in Figure 15-20.The Default Boot field displays which flash image will be used for the next boot.

15-27