HP 83620A, 24A, 22A manual Internal Pulse Mode Trigger, Invert Input

Models: 22A 24A 83620A

1 508
Download 508 pages 6.17 Kb
Page 237
Image 237

Internal Pulse Mode Trigger

Function Group (MOD)

Menu Map 4

Description This softkey (Option 002 only) lets you set the internal pulse generator to trigger on the leading edge of the externally generated pulse.

Programming Codes SCPI: PULM:INTernal:TRIGger:SOURce EXTernal

Analyzer: NONE

See Also (MOD_), also see “Pulse” and “Modulation”.

Invert Input

Function Group (MOD)

Menu Map 4

Description This softkey (Option 002 only) inverts the logic of the external pulse input. With this function active, +5 V turns off RF power.

Programming Codes SCPI: PULM:EXTernal:POLarity INVerted

Analyzer: NONE

See Also m, also see “Pulse” and “Modulation”.

l-12 Operating and Programming Reference

HP 8360

User’s

Handbook

Page 237
Image 237
HP 83620A, 24A, 22A manual Internal Pulse Mode Trigger, Invert Input