Pulse Period

Pulse Period

Function Group

Menu Map

Description

Programming Codes

(MOD)

4

This softkey lets you set a value for the internal pulse generator’s pulse period. The range of acceptable values is from 2 pus to 65.5 ms. The factory preset value is 2 ms. When this feature is active, its current value is displayed in the active entry area.

SCPI: PULSe:TIMing:PERiod <num>[time suffix] or MAXimumJMINimum

Analyzer: NONE

See Also (ALCl,m, Pulse Menu

Pulse Rate

Function Group

Menu Map

Description

Programming Codes

MODULATION

4

This softkey lets you set the internal pulse generators pulse repetition rate. The repetition rate can vary from 15.26 Hz to 500 kHz. The factory preset value is 500 Hz. When this feature is active, its current value is displayed in the active entry area.

SCPI: PULse:FREQuency <num>[freq suffix] or

MAXimumJMINimum

Analyzer: NONE

See Also (ALC),@, Pulse Menu