7(50,1$/6(59(55()(5(1&(

.MAXRETRY

This event is generated by PHONHOME, PHSYSOP, or PAGE. It will occur after the value entered for the Max. Retries system parameter is surpassed.

Example:

Alarm/Event

Action Routine

Parameters

Comments

.MAXRETRY

PHONHOME

2

 

This example initiates a PHONHOME to Home Phone Number 2, as defined in the System Parameter table, when the maximum retry counter has been exceeded.

.MDMINITERR

This alarm is generated when a modem initialization error occurs.

Alarm/Event

Action Routine

Parameters

Comments

.MDMINITERR

SNMPTRAP

1

Modem error

.MEMLOW

The alarm .MEMLOW is generated on the hour if fewer than 4KB (4096 bytes) are available on the Terminal server variable area.

Example:

Alarm/Event

Action Routine

Parameters

Comments

.MEMLOW

PHONHOME

 

Memory low

129

Page 139