7(50,1$/6(59(55()(5(1&(

Action Routines

CANCEL

This Action Routine cancels a scheduled action corresponding to a particular event containing particular parameters. When multiple pending events can be canceled, the one first into the queue is canceled.

Format:CANCEL

Resource Required: None

Parameters:ASSOCIATED EVENT, 1st Match

Parameter, 2nd Match Parameter,×××Nth Match parameter

Associated Event: Event mnemonic of the event to be canceled.

Parameters to be matched against Event: As many parameters as necessary may be specified. The position of a parameter represents the position in the event to be matched. Blank parameters are "wild cards ". Parameters are separated by commas.

Examples:

Alarm/Event

Action Routine

Parameters

Comments

.DTRLOW

CANCEL

.DTRHIGH

 

This example will cancel the action associated with the event .DTRLOW.