HP StorageWorks and McData Switch Event Codes
HP StorageWorks and McData Switch Event Codes
The following events are generated by HP StorageWorks switches and McData switches and are recorded in the Storage Management Appliance Event Log. Many of these event types have several possible states and each state has an appropriate severity code.
The Storage Management Appliance supports the following StorageWorks and McData MIB versions:
■V1.9 for the
■V1.10 for the
■V1.0 for the
Table 5: HP StorageWorks and McData Event Codes
Event | Event |
|
|
|
ID | Code | Possible States | Severity | Description |
100 | 880C0064 | N/A | 2 | An unknown trap event was received. |
|
|
|
|
|
101 | 880C0065 | online | 2 | B_Port Index %2 changed state to %1.%n |
|
| offline | 5 | A es1000PortBportScn is generated whenever |
|
| testing | 2 | a B_Port changes its operational state. |
|
| faulty | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
102 | 880C0066 | online | 2 | H_Port Index %2 changed state to %1.%n |
|
| offline | 5 | A es1000PortHportScn is generated whenever |
|
| testing | 2 | a H_Port changes its operational state |
|
| faulty | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
103 | 880C0067 | active | 2 | Component Code %2 has changed state to |
|
| updatebusy | 2 | %1.%n |
|
| failed | 7 | A es1000CompScn is generated whenever a |
|
| unknown | 0 | COMPONENT status changes its operational |
|
|
|
| state. |
|
|
|
|
|
104 | 880C0068 | online | 2 | Port Index %2 changed state to %1.%n |
|
| offline | 5 | An ed5000PortScn(1) is generated whenever |
|
| testing | 2 | a Fc_Port changes its operational state. |
|
| faulty | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
105 | 880C0069 | active | 2 | FRU Code %2 has changed state to %1.%n |
|
| backup | 3 | An ed5000FruScn(2) is generated whenever a |
|
| updatebusy | 2 | FRU status changes its operational state. |
|
| failed | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
106 | 880C006A | online | 2 | Port Index %2 changed state to %1.%n |
|
| offline | 5 | An ef6000PortScn(1) is generated whenever a |
|
| testing | 2 | Fc_Port changes its operational state. |
|
| faulty | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
107 | 880C006B | active | 2 | FRU Code %2 has changed state to %1.%n |
|
| backup | 3 | An ef6000FruScn(2) is generated whenever a |
|
| updatebusy | 2 | FRU status changes its operational state. |
|
| failed | 7 |
|
|
| unknown | 0 |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 11 |