HP StorageWorks and McData Switch Event Codes

HP StorageWorks and McData Switch Event Codes

The following events are generated by HP StorageWorks switches and McData switches and are recorded in the Storage Management Appliance Event Log. Many of these event types have several possible states and each state has an appropriate severity code.

The Storage Management Appliance supports the following StorageWorks and McData MIB versions:

V1.9 for the ED-5000 series

V1.10 for the EF-6000 series

V1.0 for the ES-1000 series

Table 5: HP StorageWorks and McData Event Codes

Event

Event

 

 

 

ID

Code

Possible States

Severity

Description

100

880C0064

N/A

2

An unknown trap event was received.

 

 

 

 

 

101

880C0065

online

2

B_Port Index %2 changed state to %1.%n

 

 

offline

5

A es1000PortBportScn is generated whenever

 

 

testing

2

a B_Port changes its operational state.

 

 

faulty

7

 

 

 

unknown

0

 

 

 

 

 

 

102

880C0066

online

2

H_Port Index %2 changed state to %1.%n

 

 

offline

5

A es1000PortHportScn is generated whenever

 

 

testing

2

a H_Port changes its operational state

 

 

faulty

7

 

 

 

unknown

0

 

 

 

 

 

 

103

880C0067

active

2

Component Code %2 has changed state to

 

 

updatebusy

2

%1.%n

 

 

failed

7

A es1000CompScn is generated whenever a

 

 

unknown

0

COMPONENT status changes its operational

 

 

 

 

state.

 

 

 

 

 

104

880C0068

online

2

Port Index %2 changed state to %1.%n

 

 

offline

5

An ed5000PortScn(1) is generated whenever

 

 

testing

2

a Fc_Port changes its operational state.

 

 

faulty

7

 

 

 

unknown

0

 

 

 

 

 

 

105

880C0069

active

2

FRU Code %2 has changed state to %1.%n

 

 

backup

3

An ed5000FruScn(2) is generated whenever a

 

 

updatebusy

2

FRU status changes its operational state.

 

 

failed

7

 

 

 

unknown

0

 

 

 

 

 

 

106

880C006A

online

2

Port Index %2 changed state to %1.%n

 

 

offline

5

An ef6000PortScn(1) is generated whenever a

 

 

testing

2

Fc_Port changes its operational state.

 

 

faulty

7

 

 

 

unknown

0

 

 

 

 

 

 

107

880C006B

active

2

FRU Code %2 has changed state to %1.%n

 

 

backup

3

An ef6000FruScn(2) is generated whenever a

 

 

updatebusy

2

FRU status changes its operational state.

 

 

failed

7

 

 

 

unknown

0

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes