HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

1027

88030403

6

4

3

Storage Cell: %1 Event Code: %2 Description: An unexpected event occurred

 

 

 

 

 

while a termination event was being processed. The value contained in the

 

 

 

 

 

uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event

 

 

 

 

 

code. 1 = Power failure before initialization could complete. 2 = Recursive

 

 

 

 

 

termination before initialization could complete. 3 = Terminated during the first

 

 

 

 

 

part post-termination preparation. 4 = Terminated during the load of the G3

 

 

 

 

 

Glue registers. 5 = Terminated during the second part post-termination

 

 

 

 

 

preparation. 6 = Terminated during event report block load. 7 = Terminated

 

 

 

 

 

during initialization of all hardware components and software data structures in

 

 

 

 

 

preparation for restart. 8 = Terminated during execution of an unrecognized

 

 

 

 

 

post-termination operation (premature). 9 = Power failure during execution of a

 

 

 

 

 

post-termination operation. A = No good entries found in Termination Event

 

 

 

 

 

Array. B = The EDC of one or more Termination Event Array entries is bad. C =

 

 

 

 

 

Terminatio n Event Array entry control block revision is different. D = Termination

 

 

 

 

 

Event Array entry information block revision is different. E = Termination Event

 

 

 

 

 

Array entry up time value is greater than the system’s up time value. F =

 

 

 

 

 

Termination Event Array entry up time value is less than the previous entry’s up

 

 

 

 

 

time value. 10= Termination Event Array entry sequence number value is less

 

 

 

 

 

than the previous entry’s sequence number value. 11= Detected an unrecognized

 

 

 

 

 

dump/restart control code. 12= Failed to terminate the entity dump loop. 13=

 

 

 

 

 

Unexpected dump entity size. 14= Unexpected Event Log Packet processing stage

 

 

 

 

 

code. 15= Number of Termination Parameters supplied not equal to maximum

 

 

 

 

 

allowed as required. The post-termination operation being performed at the time

 

 

 

 

 

the unexpected event occurred is contained in the uei.pto field.

 

 

 

 

 

Note: The lteihd and lter fields may not describe the event that caused the

 

 

 

 

 

HSV110 controller to terminate operation depending on how far t ermination

 

 

 

 

 

processing got before the unexpected event occurred.

 

 

 

 

 

 

1028

88030404

2

4

4

Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log

 

 

 

 

 

validation completed successfully. The content of the cinfo.scelcbi.status field, the

 

 

 

 

 

cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of

 

 

 

 

 

the Storage System Event Log. The meaning of the status value contained in the

 

 

 

 

 

cinfo.scelcbi.status field is as follows: 0 = No problems found.

 

 

 

 

 

Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi

 

 

 

 

 

structure is undefined.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes