HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

1554

88030612

2

6

12

Storage Cell: %1 Event Code: %2 Description: The retry count for a task

 

 

 

 

 

assigned to a Drive Enclosure Environmental Monitoring Unit has been

 

 

 

 

 

exhausted. The Fibre Channel port used to communicate with the physical disk

 

 

 

 

 

drive is contained in the cerp_id field. The HSV110 controller internal Fibre

 

 

 

 

 

Channel port number used to communicate with the physical disk drive is

 

 

 

 

 

contained in the port field. The peb array contains the task list that was intended

 

 

 

 

 

to be sent to the Drive Enclosure Environmental Monitoring Unit. The

 

 

 

 

 

peq_frz_prod_index field contains the task that was being retried. The

 

 

 

 

 

peq_prod_index field contains the drive enclosure where the physical disk drive

 

 

 

 

 

used to communicate with the Drive Enclosure Environmental Monitoring Unit is

 

 

 

 

 

located. The peq_cons_index field identifies the Fibre Channel loop pair (0 =

 

 

 

 

 

Loop A, 1 = Loop B) used to communicate with the physical disk drive that was

 

 

 

 

 

used to communicate with the Drive Enclosure Environmental Monitoring Unit.

 

 

 

 

 

The failure_cause field contains the bay where the physical disk drive used to

 

 

 

 

 

communicate with the

 

 

 

 

 

 

1555

88030613

2

6

13

Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit is able to communicate with this HSV110 controller. The identity

 

 

 

 

 

of the Drive Enclosure Environmental Monitoring Unit is contained in the device

 

 

 

 

 

field. The Fibre Channel port used to communicate with the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit is contained in the cerp_id field. The HSV110

 

 

 

 

 

controller internal Fibre Channel port number used to communicate with the

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit is contained in the port field. The

 

 

 

 

 

location of the Drive Enclosure Environmental Monitoring Unit is contained in the

 

 

 

 

 

rack_num and dencl_num fields. The rack_num field will not be valid until a

 

 

 

 

 

future release. Note that in this case the content of the bay, fed_class and

 

 

 

 

 

num_times fields is undefined.

 

 

 

 

 

 

1556

88030614

6

6

14

Storage Cell: %1 Event Code: %2 Description: There are too many drive

 

 

 

 

 

enclosures. The Fibre Channel port with too many drive enclosures attached to

 

 

 

 

 

the HSV110 controller is contained in the cerp_id field. Note that in this case the

 

 

 

 

 

content of the bay, fed_class, rack_num, dencl_num and num_times fields is

 

 

 

 

 

undefined.

 

 

 

 

 

 

1557

88030615

6

6

15

Storage Cell: %1 Event Code: %2 Description: The cable connected to the I/O

 

 

 

 

 

module is attached to the wrong Fibre Channel port. The Fibre Channel port

 

 

 

 

 

incorrectly attached to the HSV110 controller is contained in the cerp_id field.

 

 

 

 

 

Note that in this case the content of the bay, fed_class, rack_num, dencl_num

 

 

 

 

 

and num_times fields is undefined.

 

 

 

 

 

 

1558

88030616

6

6

16

Storage Cell: %1 Event Code: %2 Description: A HSV110 controller does not

 

 

 

 

 

have an address on the enclosure address bus. The HSV110 controller location

 

 

 

 

 

cannot be identified. Note that in this case the content of the bay, fed_class,

 

 

 

 

 

rack_num, dencl_num, alpa, device, cerp_id, port, and num_times fields are

 

 

 

 

 

undefined.

 

 

 

 

 

 

1559

88030617

6

6

17

Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit has detected a physical disk drive that was preventing proper

 

 

 

 

 

loop operation. The physical disk drive has been bypassed and is ready for

 

 

 

 

 

replacement. The location of this physical disk drive is specified by the

 

 

 

 

 

rack_num, bay, and dencl_num fields. The rack_num field will not be valid until

 

 

 

 

 

a future release. The identity of the Drive Enclosure Environmental Monitoring

 

 

 

 

 

Unit is contained in the device field. The UUID of the specific physical disk drive

 

 

 

 

 

is not identifiable. Check the fault lights of the enclosure associated with this Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit. Note that in this case the content of

 

 

 

 

 

the fed_class, alpa, and num_times fields are undefined.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

31