| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1554 | 88030612 | 2 | 6 | 12 | Storage Cell: %1 Event Code: %2 Description: The retry count for a task |
|
|
|
|
| assigned to a Drive Enclosure Environmental Monitoring Unit has been |
|
|
|
|
| exhausted. The Fibre Channel port used to communicate with the physical disk |
|
|
|
|
| drive is contained in the cerp_id field. The HSV110 controller internal Fibre |
|
|
|
|
| Channel port number used to communicate with the physical disk drive is |
|
|
|
|
| contained in the port field. The peb array contains the task list that was intended |
|
|
|
|
| to be sent to the Drive Enclosure Environmental Monitoring Unit. The |
|
|
|
|
| peq_frz_prod_index field contains the task that was being retried. The |
|
|
|
|
| peq_prod_index field contains the drive enclosure where the physical disk drive |
|
|
|
|
| used to communicate with the Drive Enclosure Environmental Monitoring Unit is |
|
|
|
|
| located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = |
|
|
|
|
| Loop A, 1 = Loop B) used to communicate with the physical disk drive that was |
|
|
|
|
| used to communicate with the Drive Enclosure Environmental Monitoring Unit. |
|
|
|
|
| The failure_cause field contains the bay where the physical disk drive used to |
|
|
|
|
| communicate with the |
|
|
|
|
|
|
1555 | 88030613 | 2 | 6 | 13 | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is able to communicate with this HSV110 controller. The identity |
|
|
|
|
| of the Drive Enclosure Environmental Monitoring Unit is contained in the device |
|
|
|
|
| field. The Fibre Channel port used to communicate with the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 |
|
|
|
|
| controller internal Fibre Channel port number used to communicate with the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit is contained in the port field. The |
|
|
|
|
| location of the Drive Enclosure Environmental Monitoring Unit is contained in the |
|
|
|
|
| rack_num and dencl_num fields. The rack_num field will not be valid until a |
|
|
|
|
| future release. Note that in this case the content of the bay, fed_class and |
|
|
|
|
| num_times fields is undefined. |
|
|
|
|
|
|
1556 | 88030614 | 6 | 6 | 14 | Storage Cell: %1 Event Code: %2 Description: There are too many drive |
|
|
|
|
| enclosures. The Fibre Channel port with too many drive enclosures attached to |
|
|
|
|
| the HSV110 controller is contained in the cerp_id field. Note that in this case the |
|
|
|
|
| content of the bay, fed_class, rack_num, dencl_num and num_times fields is |
|
|
|
|
| undefined. |
|
|
|
|
|
|
1557 | 88030615 | 6 | 6 | 15 | Storage Cell: %1 Event Code: %2 Description: The cable connected to the I/O |
|
|
|
|
| module is attached to the wrong Fibre Channel port. The Fibre Channel port |
|
|
|
|
| incorrectly attached to the HSV110 controller is contained in the cerp_id field. |
|
|
|
|
| Note that in this case the content of the bay, fed_class, rack_num, dencl_num |
|
|
|
|
| and num_times fields is undefined. |
|
|
|
|
|
|
1558 | 88030616 | 6 | 6 | 16 | Storage Cell: %1 Event Code: %2 Description: A HSV110 controller does not |
|
|
|
|
| have an address on the enclosure address bus. The HSV110 controller location |
|
|
|
|
| cannot be identified. Note that in this case the content of the bay, fed_class, |
|
|
|
|
| rack_num, dencl_num, alpa, device, cerp_id, port, and num_times fields are |
|
|
|
|
| undefined. |
|
|
|
|
|
|
1559 | 88030617 | 6 | 6 | 17 | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit has detected a physical disk drive that was preventing proper |
|
|
|
|
| loop operation. The physical disk drive has been bypassed and is ready for |
|
|
|
|
| replacement. The location of this physical disk drive is specified by the |
|
|
|
|
| rack_num, bay, and dencl_num fields. The rack_num field will not be valid until |
|
|
|
|
| a future release. The identity of the Drive Enclosure Environmental Monitoring |
|
|
|
|
| Unit is contained in the device field. The UUID of the specific physical disk drive |
|
|
|
|
| is not identifiable. Check the fault lights of the enclosure associated with this Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit. Note that in this case the content of |
|
|
|
|
| the fed_class, alpa, and num_times fields are undefined. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 31 |