HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1029 | 88030405 | 2 | 4 | 5 | Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log |
|
|
|
|
| validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi |
|
|
|
|
| structure, and the minfo.scelmi structure show the state of the Storage System |
|
|
|
|
| Event Log at the time of the failure. The content and state of the Storage System |
|
|
|
|
| Event Log have been initialized to their initial operational settings. The meaning |
|
|
|
|
| of the status value contained in the cinfo.scelcbi.status field is as follows: 1 = |
|
|
|
|
| Cookie value is not as expected. 2 = Event data overflows the buffer. 3 = Event |
|
|
|
|
| data size is not a multiple of 4 bytes, is less than the minimum, or is greater than |
|
|
|
|
| the maximum. 4 = Event Information Packet type is greater than the maximum. 5 |
|
|
|
|
| = Event information size is not a multiple of 4 bytes, is less than the minimum, is |
|
|
|
|
| greater than the maximum, doesn’t match the Event Information Packet type size, |
|
|
|
|
| or when combined with the entry header size doesn’t equal the entry size. 6 = |
|
|
|
|
| Event code is zero. 7 = Event is out of sequence. 8 = Dead space area at the end |
|
|
|
|
| of a partially packed buffer contains a nonzero value. 9 = An event data block |
|
|
|
|
| containing a nonzero value was found after end of event data was detected. A = |
|
|
|
|
| Sequence number reset flag not set as expected. B = The event log contains no |
|
|
|
|
| entries. C = Event data block read failed during maintenance verification. D = |
|
|
|
|
| Event data block read failed during maintenance completion. E = Event data |
|
|
|
|
| block erase failed during maintenance completion. F = Control block read failed |
|
|
|
|
| during maintenance verification. |
|
|
|
|
| Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi |
|
|
|
|
| structure is undefined. |
|
|
|
|
|
|
1030 | 88030406 | 6 | 4 | 6 | Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an |
|
|
|
|
| insufficient supply of Event Log Packets on the HSV110 controller that is the |
|
|
|
|
| Storage System Master. The ainfo.events_not_reported field shows the number of |
|
|
|
|
| event reports lost. |
|
|
|
|
| Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field |
|
|
|
|
| cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined. |
|
|
|
|
|
|
1031 | 88030407 | 6 | 4 | 7 | Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an |
|
|
|
|
| insufficient supply of Event Log Packets on the HSV110 controller that is not the |
|
|
|
|
| Storage System Master. The ainfo.events_not_reported field shows the number of |
|
|
|
|
| event reports lost. |
|
|
|
|
| Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field |
|
|
|
|
| cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined. |
|
|
|
|
|
|
1032 | 88030408 | 2 | 4 | 8 | Storage Cell: %1 Event Code: %2 Description: The Storage System Termination |
|
|
|
|
| Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field, |
|
|
|
|
| the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state |
|
|
|
|
| of the Storage System Termination Event Log. The meaning of the status value |
|
|
|
|
| contained in the cinfo.sctelcbi.status field is as follows: F = Control block read |
|
|
|
|
| failed during maintenance verification. 10= Control block read failed during |
|
|
|
|
| maintenance verification. 11= Event data block write failed during maintenance |
|
|
|
|
| update. 12= Control block write failed during maintenance completion. 13= |
|
|
|
|
| Storage System Termination Event Log related send was unsuccessful or the |
|
|
|
|
| master found that the Storage System Termination Event Log is inaccessible. 16= |
|
|
|
|
| Event data block read failed during retrieval request. |
|
|
|
|
| Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi |
|
|
|
|
| structure is undefined. |
|
|
|
|
|
|
24 | Storage Management Appliance Software Event Code Definitions Application Notes |