HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3082

88030c0a

2

c

a

Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has

 

 

 

 

 

been reset due to site failover. The following fields are not valid: status, blocks,

 

 

 

 

 

vda.

 

 

 

 

 

 

3084

88030c0c

2

c

c

Storage Cell: %1 Event Code: %2 Description: The specified destination virtual

 

 

 

 

 

disk has successfully completed a merge. The following fields are not valid:

 

 

 

 

 

status, blocks, vda.

 

 

 

 

 

 

3087

88030c0f

2

c

f

Storage Cell: %1 Event Code: %2 Description: The specified virtual disk is no

 

 

 

 

 

longer failsafe locked. The following fields are not valid: status, blocks, vda, port,

 

 

 

 

 

side.

 

 

 

 

 

 

3088

88030c10

2

c

10

Storage Cell: %1 Event Code: %2 Description: The specified destination virtual

 

 

 

 

 

disk has been marked for a full copy. The following fields are not valid: status,

 

 

 

 

 

blocks, vda.

 

 

 

 

 

 

3089

88030c11

2

c

11

Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a

 

 

 

 

 

site failover has taken place. This group is transitioning from a source role to a

 

 

 

 

 

destination role. The following fields are not valid: status, blocks, vda.

 

 

 

 

 

 

3090

88030c12

2

c

12

Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a

 

 

 

 

 

site failover has taken place. This group is transitioning from a destination role to

 

 

 

 

 

a source role. The following fields are not valid: status, blocks, vda.

 

 

 

 

 

 

3092

88030c14

6

c

14

Storage Cell: %1 Event Code: %2 Description: The specified destination DRM

 

 

 

 

 

group was not found. The destination group appears to have been deleted by

 

 

 

 

 

the user after a site failover, therefore this dangling DRM source group should

 

 

 

 

 

likewise be deleted.

 

 

 

 

 

 

3328

88030d00

6

d

0

Storage Cell: %1 Event Code: %2 Description: Unrecognized event reported by

 

 

 

 

 

a Drive Enclosure Environmental Monitoring Unit. The event was reported by the

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. The content of the

 

 

 

 

 

alarm_error_code field could not be translated into a known event.

 

 

 

 

 

 

3329

88030d01

6

d

1

Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is not

 

 

 

 

 

Fibre Channel compatible or cannot operate at the link rate established by the

 

 

 

 

 

drive enclosure I/O modules was detected. This problem was detected by the

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field

 

 

 

 

 

during spin up of the physical disk drive installed in the drive enclosure bay

 

 

 

 

 

identified in the alarm_error_code.field.en field. The rack_num field will not be

 

 

 

 

 

valid until a future release.

 

 

 

 

 

 

3330

88030d02

3

d

2

Storage Cell: %1 Event Code: %2 Description: A physical disk drive is

 

 

 

 

 

improperly installed or missing. This could affect the drive enclosure air flow and

 

 

 

 

 

cause an over temperature condition. This problem was detected by the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit located in the drive enclosure identified

 

 

 

 

 

in the dencl_num field within the rack identified in the rack_num field. The

 

 

 

 

 

rack_num field will not be valid until a future release. The affected drive enclosure

 

 

 

 

 

bay is identified in the alarm_error_code.field.en field.

 

 

 

 

 

 

3331

88030d03

3

d

3

Storage Cell: %1 Event Code: %2 Description: A physical disk drive was

 

 

 

 

 

removed while software-activated drive locking was enabled on a drive enclosure

 

 

 

 

 

that does not support drive locking. This problem was detected by the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit located in the drive enclosure identified

 

 

 

 

 

in the dencl_num field within the rack identified in the rack_num field. The

 

 

 

 

 

rack_num field will not be valid until a future release. The affected drive enclosure

 

 

 

 

 

bay is identified in the alarm_error_code.field.en field.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

45