| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
3082 | 88030c0a | 2 | c | a | Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has |
|
|
|
|
| been reset due to site failover. The following fields are not valid: status, blocks, |
|
|
|
|
| vda. |
|
|
|
|
|
|
3084 | 88030c0c | 2 | c | c | Storage Cell: %1 Event Code: %2 Description: The specified destination virtual |
|
|
|
|
| disk has successfully completed a merge. The following fields are not valid: |
|
|
|
|
| status, blocks, vda. |
|
|
|
|
|
|
3087 | 88030c0f | 2 | c | f | Storage Cell: %1 Event Code: %2 Description: The specified virtual disk is no |
|
|
|
|
| longer failsafe locked. The following fields are not valid: status, blocks, vda, port, |
|
|
|
|
| side. |
|
|
|
|
|
|
3088 | 88030c10 | 2 | c | 10 | Storage Cell: %1 Event Code: %2 Description: The specified destination virtual |
|
|
|
|
| disk has been marked for a full copy. The following fields are not valid: status, |
|
|
|
|
| blocks, vda. |
|
|
|
|
|
|
3089 | 88030c11 | 2 | c | 11 | Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a |
|
|
|
|
| site failover has taken place. This group is transitioning from a source role to a |
|
|
|
|
| destination role. The following fields are not valid: status, blocks, vda. |
|
|
|
|
|
|
3090 | 88030c12 | 2 | c | 12 | Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a |
|
|
|
|
| site failover has taken place. This group is transitioning from a destination role to |
|
|
|
|
| a source role. The following fields are not valid: status, blocks, vda. |
|
|
|
|
|
|
3092 | 88030c14 | 6 | c | 14 | Storage Cell: %1 Event Code: %2 Description: The specified destination DRM |
|
|
|
|
| group was not found. The destination group appears to have been deleted by |
|
|
|
|
| the user after a site failover, therefore this dangling DRM source group should |
|
|
|
|
| likewise be deleted. |
|
|
|
|
|
|
3328 | 88030d00 | 6 | d | 0 | Storage Cell: %1 Event Code: %2 Description: Unrecognized event reported by |
|
|
|
|
| a Drive Enclosure Environmental Monitoring Unit. The event was reported by the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. |
|
|
|
|
| The rack_num field will not be valid until a future release. The content of the |
|
|
|
|
| alarm_error_code field could not be translated into a known event. |
|
|
|
|
|
|
3329 | 88030d01 | 6 | d | 1 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is not |
|
|
|
|
| Fibre Channel compatible or cannot operate at the link rate established by the |
|
|
|
|
| drive enclosure I/O modules was detected. This problem was detected by the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field |
|
|
|
|
| during spin up of the physical disk drive installed in the drive enclosure bay |
|
|
|
|
| identified in the alarm_error_code.field.en field. The rack_num field will not be |
|
|
|
|
| valid until a future release. |
|
|
|
|
|
|
3330 | 88030d02 | 3 | d | 2 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive is |
|
|
|
|
| improperly installed or missing. This could affect the drive enclosure air flow and |
|
|
|
|
| cause an over temperature condition. This problem was detected by the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit located in the drive enclosure identified |
|
|
|
|
| in the dencl_num field within the rack identified in the rack_num field. The |
|
|
|
|
| rack_num field will not be valid until a future release. The affected drive enclosure |
|
|
|
|
| bay is identified in the alarm_error_code.field.en field. |
|
|
|
|
|
|
3331 | 88030d03 | 3 | d | 3 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive was |
|
|
|
|
| removed while |
|
|
|
|
| that does not support drive locking. This problem was detected by the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit located in the drive enclosure identified |
|
|
|
|
| in the dencl_num field within the rack identified in the rack_num field. The |
|
|
|
|
| rack_num field will not be valid until a future release. The affected drive enclosure |
|
|
|
|
| bay is identified in the alarm_error_code.field.en field. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 45 |