HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3441

88030d71

2

d

71

Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit error has occurred. This problem was detected by

 

 

 

 

 

the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element. The cause of

 

 

 

 

 

the improper operation is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 3 = A drive enclosure power supply

 

 

 

 

 

was shut down. 16 = The Drive Enclosure Environmental Monitoring Unit ESI data

 

 

 

 

 

has been corrupted.

 

 

 

 

 

 

3442

88030d72

3

d

72

Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit is unable to collect data for the SCSI-3 Engineering Services

 

 

 

 

 

(SES) page. This problem was detected by the Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit located in the drive enclosure identified in the dencl_num field

 

 

 

 

 

within the rack identified in the rack_num field. The rack_num field will not be

 

 

 

 

 

valid until a future release. The alarm_error_code.field.en field contains the value

 

 

 

 

 

1 signifying that the Drive Enclosure Environmental Monitoring Unit is the

 

 

 

 

 

affected element.

 

 

 

 

 

 

3454

88030d7e

3

d

7e

Storage Cell: %1 Event Code: %2 Description: Invalid data was read from a

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit NVRAM. This problem was

 

 

 

 

 

detected by the Drive Enclosure Environmental Monitoring Unit located in the

 

 

 

 

 

drive enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element.

 

 

 

 

 

 

3455

88030d7f

3

d

7f

Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit error has occurred. This problem was detected by

 

 

 

 

 

the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element. The cause of

 

 

 

 

 

the improper operation is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 11 = The Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit cannot write data to the NVRAM. 12 = The Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. 13

 

 

 

 

 

= The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to

 

 

 

 

 

load information required for Drive Enclosure Environmental Monitoring Unit

 

 

 

 

 

operation.

 

 

 

 

 

 

3458

88030d82

3

d

82

Storage Cell: %1 Event Code: %2 Description: A drive enclosure’s address is

 

 

 

 

 

incorrect or the enclosure has no address. This problem was detected by the

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

49