| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
3441 | 88030d71 | 2 | d | 71 | Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit error has occurred. This problem was detected by |
|
|
|
|
| the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. |
|
|
|
|
| The rack_num field will not be valid until a future release. The |
|
|
|
|
| alarm_error_code.field.en field contains the value 1 signifying that the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit is the affected element. The cause of |
|
|
|
|
| the improper operation is described by the content of the |
|
|
|
|
| alarm_error_code.field.ec field as follows: 3 = A drive enclosure power supply |
|
|
|
|
| was shut down. 16 = The Drive Enclosure Environmental Monitoring Unit ESI data |
|
|
|
|
| has been corrupted. |
|
|
|
|
|
|
3442 | 88030d72 | 3 | d | 72 | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is unable to collect data for the |
|
|
|
|
| (SES) page. This problem was detected by the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit located in the drive enclosure identified in the dencl_num field |
|
|
|
|
| within the rack identified in the rack_num field. The rack_num field will not be |
|
|
|
|
| valid until a future release. The alarm_error_code.field.en field contains the value |
|
|
|
|
| 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the |
|
|
|
|
| affected element. |
|
|
|
|
|
|
3454 | 88030d7e | 3 | d | 7e | Storage Cell: %1 Event Code: %2 Description: Invalid data was read from a |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit NVRAM. This problem was |
|
|
|
|
| detected by the Drive Enclosure Environmental Monitoring Unit located in the |
|
|
|
|
| drive enclosure identified in the dencl_num field within the rack identified in the |
|
|
|
|
| rack_num field. The rack_num field will not be valid until a future release. The |
|
|
|
|
| alarm_error_code.field.en field contains the value 1 signifying that the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit is the affected element. |
|
|
|
|
|
|
3455 | 88030d7f | 3 | d | 7f | Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit error has occurred. This problem was detected by |
|
|
|
|
| the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. |
|
|
|
|
| The rack_num field will not be valid until a future release. The |
|
|
|
|
| alarm_error_code.field.en field contains the value 1 signifying that the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit is the affected element. The cause of |
|
|
|
|
| the improper operation is described by the content of the |
|
|
|
|
| alarm_error_code.field.ec field as follows: 11 = The Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit cannot write data to the NVRAM. 12 = The Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. 13 |
|
|
|
|
| = The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to |
|
|
|
|
| load information required for Drive Enclosure Environmental Monitoring Unit |
|
|
|
|
| operation. |
|
|
|
|
|
|
3458 | 88030d82 | 3 | d | 82 | Storage Cell: %1 Event Code: %2 Description: A drive enclosure’s address is |
|
|
|
|
| incorrect or the enclosure has no address. This problem was detected by the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. |
|
|
|
|
| The rack_num field will not be valid until a future release. The |
|
|
|
|
| alarm_error_code.field.en field contains the value 1 signifying that the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit is the affected element. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 49 |