HSV Element Manager Event Codes

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

1543

88030607

3

6

7

Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service

 

 

 

 

 

Descriptor frame sent to a physical disk drive has timed out. The identity of the

 

 

 

 

 

physical disk drive is contained in the device field. The Fibre Channel port used

 

 

 

 

 

to communicate with the physical disk drive is contained in the cerp_id field. The

 

 

 

 

 

HSV110 controller internal Fibre Channel port number used to communicate with

 

 

 

 

 

the physical disk drive is contained in the port field. The arbitrated loop physical

 

 

 

 

 

address of the physical disk drive is contained in the al_pa field. If the bay field

 

 

 

 

 

contains a value other than zero, the location of the physical disk drive is

 

 

 

 

 

contained in the rack_num, dencl_num, and bay fields. If the bay field contains

 

 

 

 

 

a zero, the location of the physical disk drive is unknown and the content of the

 

 

 

 

 

rack_num and dencl_num fields is undefined. The rack_num field will not be

 

 

 

 

 

valid until a future release. The Fibre Channel Exchange Descriptor class is

 

 

 

 

 

contained in the fed_class field. The command issued to the physical disk drive is

 

 

 

 

 

contained in th e cmd field. Note that in this case the content of the error field is

 

 

 

 

 

undefined.

 

 

 

 

 

 

1544

88030608

2

6

8

Storage Cell: %1 Event Code: %2 Description: An excessive number of link

 

 

 

 

 

errors were detected on a HSV110 controller’s Fibre Channel port. The identity

 

 

 

 

 

of the affected Fibre Channel port is contained in the cerp_id field. The HSV110

 

 

 

 

 

controller internal Fibre Channel port number of the affected Fibre Channel port

 

 

 

 

 

is contained in the port field. This is an informational event triggered by the

 

 

 

 

 

occurrence of an excessive number of Tachyon chip link status errors detected

 

 

 

 

 

within a particular link status error type. The number of occurrences of each link

 

 

 

 

 

status error type is contained in a separate type-specific field (e.g.,

 

 

 

 

 

loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its

 

 

 

 

 

Fibre Channel port’s for excessive link status errors periodicaly.

 

 

 

 

 

 

1545

88030609

6

6

9

Storage Cell: %1 Event Code: %2 Description: A physical disk drive has

 

 

 

 

 

reported numerous failure prediction threshold exceeded errors. The identity of

 

 

 

 

 

the physical disk drive is contained in the device field. The Fibre Channel port

 

 

 

 

 

used to communicate with the physical disk drive is contained in the cerp_id field.

 

 

 

 

 

The HSV110 controller internal Fibre Channel port number used to communicate

 

 

 

 

 

with the physical disk drive is contained in the port field. The arbitrated loop

 

 

 

 

 

physical address of the physical disk drive is contained in the al_pa field. If the

 

 

 

 

 

bay field contains a value other than zero, the location of the physical disk drive

 

 

 

 

 

is contained in the rack_num, dencl_num, and bay fields. If the bay field contains

 

 

 

 

 

a zero, the location of the physical disk drive is unknown and the content of the

 

 

 

 

 

rack_num and dencl_num fields is undefined. The rack_num field will not be

 

 

 

 

 

valid until a future release. The Fibre Channel Exchange Descriptor class is

 

 

 

 

 

contained in the fed_class field. The num_times field is the number of failure

 

 

 

 

 

prediction threshol d exceeded errors reported by the physical disk drive in the

 

 

 

 

 

previous minute.

 

 

 

 

 

 

28