HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1543 | 88030607 | 3 | 6 | 7 | Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service |
|
|
|
|
| Descriptor frame sent to a physical disk drive has timed out. The identity of the |
|
|
|
|
| physical disk drive is contained in the device field. The Fibre Channel port used |
|
|
|
|
| to communicate with the physical disk drive is contained in the cerp_id field. The |
|
|
|
|
| HSV110 controller internal Fibre Channel port number used to communicate with |
|
|
|
|
| the physical disk drive is contained in the port field. The arbitrated loop physical |
|
|
|
|
| address of the physical disk drive is contained in the al_pa field. If the bay field |
|
|
|
|
| contains a value other than zero, the location of the physical disk drive is |
|
|
|
|
| contained in the rack_num, dencl_num, and bay fields. If the bay field contains |
|
|
|
|
| a zero, the location of the physical disk drive is unknown and the content of the |
|
|
|
|
| rack_num and dencl_num fields is undefined. The rack_num field will not be |
|
|
|
|
| valid until a future release. The Fibre Channel Exchange Descriptor class is |
|
|
|
|
| contained in the fed_class field. The command issued to the physical disk drive is |
|
|
|
|
| contained in th e cmd field. Note that in this case the content of the error field is |
|
|
|
|
| undefined. |
|
|
|
|
|
|
1544 | 88030608 | 2 | 6 | 8 | Storage Cell: %1 Event Code: %2 Description: An excessive number of link |
|
|
|
|
| errors were detected on a HSV110 controller’s Fibre Channel port. The identity |
|
|
|
|
| of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 |
|
|
|
|
| controller internal Fibre Channel port number of the affected Fibre Channel port |
|
|
|
|
| is contained in the port field. This is an informational event triggered by the |
|
|
|
|
| occurrence of an excessive number of Tachyon chip link status errors detected |
|
|
|
|
| within a particular link status error type. The number of occurrences of each link |
|
|
|
|
| status error type is contained in a separate |
|
|
|
|
| loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its |
|
|
|
|
| Fibre Channel port’s for excessive link status errors periodicaly. |
|
|
|
|
|
|
1545 | 88030609 | 6 | 6 | 9 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive has |
|
|
|
|
| reported numerous failure prediction threshold exceeded errors. The identity of |
|
|
|
|
| the physical disk drive is contained in the device field. The Fibre Channel port |
|
|
|
|
| used to communicate with the physical disk drive is contained in the cerp_id field. |
|
|
|
|
| The HSV110 controller internal Fibre Channel port number used to communicate |
|
|
|
|
| with the physical disk drive is contained in the port field. The arbitrated loop |
|
|
|
|
| physical address of the physical disk drive is contained in the al_pa field. If the |
|
|
|
|
| bay field contains a value other than zero, the location of the physical disk drive |
|
|
|
|
| is contained in the rack_num, dencl_num, and bay fields. If the bay field contains |
|
|
|
|
| a zero, the location of the physical disk drive is unknown and the content of the |
|
|
|
|
| rack_num and dencl_num fields is undefined. The rack_num field will not be |
|
|
|
|
| valid until a future release. The Fibre Channel Exchange Descriptor class is |
|
|
|
|
| contained in the fed_class field. The num_times field is the number of failure |
|
|
|
|
| prediction threshol d exceeded errors reported by the physical disk drive in the |
|
|
|
|
| previous minute. |
|
|
|
|
|
|
28 | Storage Management Appliance Software Event Code Definitions Application Notes |