HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1536 | 88030600 | 6 | 6 | 0 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive has |
|
|
|
|
| reported that it has exceeded its failure prediction threshold. The identity of the |
|
|
|
|
| physical disk drive is contained in the device field. The Fibre Channel port used |
|
|
|
|
| to communicate with the physical disk drive is contained in the cerp_id field. The |
|
|
|
|
| HSV110 controller internal Fibre Channel port number used to communicate with |
|
|
|
|
| the physical disk drive is contained in the port field. The arbitrated loop physical |
|
|
|
|
| address of the physical disk drive is contained in the al_pa field. If the bay field |
|
|
|
|
| contains a value other than zero, the location of the physical disk drive is |
|
|
|
|
| contained in the rack_num, dencl_num, and bay fields. If the bay field contains |
|
|
|
|
| a zero, the location of the physical disk drive is unknown and the content of the |
|
|
|
|
| rack_num and dencl_num fields is undefined. The rack_num field will not be |
|
|
|
|
| valid until a future release. The Fibre Channel Exchange Descriptor class is |
|
|
|
|
| contained in the fed_class field. The command issued to the physical disk drive is |
|
|
|
|
| contained in t he cmd field. The sense data obtained from the physical disk drive |
|
|
|
|
| as a result of the failure prediction threshold exceeded error is contained in the |
|
|
|
|
| error field. |
|
|
|
|
|
|
1537 | 88030601 | 3 | 6 | 1 | Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the |
|
|
|
|
| HSV110 controller has failed to respond. The identity of the affected Fibre |
|
|
|
|
| Channel port is contained in the cerp_id field. The HSV110 controller internal |
|
|
|
|
| Fibre Channel port number of the affected Fibre Channel port is contained in the |
|
|
|
|
| port field. The peb array contains the port event block information. The |
|
|
|
|
| peq_frz_prod_index field contains the index to the port event block in use when |
|
|
|
|
| the Tachyon chip entered the frozen state. The peq_prod_index field contains the |
|
|
|
|
| index to the next port event block. The peq_cons_index field contains the index |
|
|
|
|
| to the next port event block to be acted upon. The failure_cause field contains the |
|
|
|
|
| internal routing. |
|
|
|
|
|
|
1538 | 88030602 | 2 | 6 | 2 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive has |
|
|
|
|
| reported a check condition error. The identity of the physical disk drive is |
|
|
|
|
| contained in the device field. The Fibre Channel port used to communicate with |
|
|
|
|
| the physical disk drive is contained in the cerp_id field. The HSV110 controller |
|
|
|
|
| internal Fibre Channel port number used to communicate with the physical disk |
|
|
|
|
| drive is contained in the port field. The arbitrated loop physical address of the |
|
|
|
|
| physical disk drive is contained in the al_pa field. If the bay field contains a |
|
|
|
|
| value other than zero, the location of the physical disk drive is contained in the |
|
|
|
|
| rack_num, dencl_num, and bay fields. If the bay field contains a zero, the |
|
|
|
|
| location of the physical disk drive is unknown and the content of the rack_num |
|
|
|
|
| and dencl_num fields is undefined. The rack_num field will not be valid until a |
|
|
|
|
| future release. The Fibre Channel Exchange Descriptor class is contained in the |
|
|
|
|
| fed_class field. The command issued to the physical disk drive is contained in the |
|
|
|
|
| cmd field. The sense data obt ained from the physical disk drive as a result of the |
|
|
|
|
| check condition error is contained in the error field. |
|
|
|
|
|
|
26 | Storage Management Appliance Software Event Code Definitions Application Notes |