HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

 

Description

ID

Code

erity

ID

No.

 

1546

8803060a

2

6

a

Storage Cell: %1

Event Code: %2 Description: A physical disk drive has

 

 

 

 

 

reported numerous check condition errors. The identity of the physical disk drive

 

 

 

 

 

is contained in the device field. The Fibre Channel port used to communicate

 

 

 

 

 

with the physical disk drive is contained in the cerp_id field. The HSV110

 

 

 

 

 

controller internal Fibre Channel port number used to communicate with the

 

 

 

 

 

physical disk drive is contained in the port field. The arbitrated loop physical

 

 

 

 

 

address of the physical disk drive is contained in the al_pa field. If the bay field

 

 

 

 

 

contains a value other than zero, the location of the physical disk drive is

 

 

 

 

 

contained in the rack_num, dencl_num, and bay fields. If the bay field contains

 

 

 

 

 

a zero, the location of the physical disk drive is unknown and the content of the

 

 

 

 

 

rack_num and dencl_num fields is undefined. The rack_num field will not be

 

 

 

 

 

valid until a future release. The Fibre Channel Exchange Descriptor class is

 

 

 

 

 

contained in the fed_class field. The num_times field is the number of check

 

 

 

 

 

condition errors reported by the physical disk drive in the previous minute.

 

 

 

 

 

 

1547

8803060b

3

6

b

Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent

 

 

 

 

 

to a physical disk drive has timed out. The identity of the physical disk drive is

 

 

 

 

 

contained in the device field. The Fibre Channel port used to communicate with

 

 

 

 

 

the physical disk drive is contained in the cerp_id field. The HSV110 controller

 

 

 

 

 

internal Fibre Channel port number used to communicate with the physical disk

 

 

 

 

 

drive is contained in the port field. The arbitrated loop physical address of the

 

 

 

 

 

physical disk drive is contained in the al_pa field. If the bay field contains a

 

 

 

 

 

value other than zero, the location of the physical disk drive is contained in the

 

 

 

 

 

rack_num, dencl_num, and bay fields. If the bay field contains a zero, the

 

 

 

 

 

location of the physical disk drive is unknown and the content of the rack_num

 

 

 

 

 

and dencl_num fields is undefined. The rack_num field will not be valid until a

 

 

 

 

 

future release. The Fibre Channel Exchange Descriptor class is contained in the

 

 

 

 

 

fed_class field. The command issued to the physical disk drive is contained in the

 

 

 

 

 

cmd field. Note

that in this case the content of the error field is undefined.

 

 

 

 

 

 

 

1548

8803060c

2

6

c

Storage Cell: %1

Event Code: %2 Description: A loop switch has been detected

 

 

 

 

 

on a Fibre Channel port. The identity of the Fibre Channel port is contained in

 

 

 

 

 

the cerp_id field. The HSV110 controller internal Fibre Channel port number is

 

 

 

 

 

contained in the port field. Note that in this case the device, al_pa, rack_num,

 

 

 

 

 

dencl_num, bay, fed_class and num_times fields are undefined.

 

 

 

 

 

 

 

1549

8803060d

2

6

d

Storage Cell: %1

Event Code: %2 Description: The location of a physical disk

 

 

 

 

 

drive previously reported as unknown is now known. The identity of the physical

 

 

 

 

 

disk drive is contained in the device field. The Fibre Channel port used to

 

 

 

 

 

communicate with the physical disk drive is contained in the cerp_id field. The

 

 

 

 

 

HSV110 controller internal Fibre Channel port number used to communicate with

 

 

 

 

 

the physical disk drive is contained in the port field. The arbitrated loop physical

 

 

 

 

 

address of the physical disk drive is contained in the al_pa field. The location of

 

 

 

 

 

the physical disk drive is contained in the rack_num, dencl_num, and bay fields.

 

 

 

 

 

The rack_num field will not be valid until a future release. Note that in this case

 

 

 

 

 

the content of the fed_class and num_times fields is undefined.

 

 

 

 

 

 

 