HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3399

88030d47

6

d

47

Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is not

 

 

 

 

 

operating properly. This could affect the drive enclosure air flow and cause an

 

 

 

 

 

over temperature condition. This problem was detected by the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit located in the drive enclosure identified in the

 

 

 

 

 

dencl_num field within the rack identified in the rack_num field.The rack_num

 

 

 

 

 

field will not be valid until a future release. The location of the affected blower (1

 

 

 

 

 

or 2) is identified in the alarm_error_code.field.en field. The cause of the

 

 

 

 

 

improper operation is described by the content of the alarm_error_code.field.ec

 

 

 

 

 

field as follows: 1 = The blower is operating at a speed that is outside of the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit specified range, possibly because of a

 

 

 

 

 

bearing problem. 2 = The blower is operating at a speed that is significantly

 

 

 

 

 

outside of the Drive Enclosure Environmental Monitoring Unit specified range,

 

 

 

 

 

possibly because of a bearing problem. 3 = The blower has stopped.

 

 

 

 

 

NOTE: The other blower (if operational) now operates at high speed and is a

 

 

 

 

 

single point of failure. A single blower operating at high speed can provide

 

 

 

 

 

sufficient air flow to cool an enclosure and the elements for up to 100 hours.

 

 

 

 

 

However, operating an enclosure at temperatures approaching an overheating

 

 

 

 

 

threshold can damage elements and may reduce the MTBF of a specific element.

 

 

 

 

 

Compaq therefore recommends immediate replacement of the defective blower.

 

 

 

 

 

4 = The power supply reported an internal blower error.

 

 

 

 

 

 

3403

88030d4b

6

d

4b

Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is

 

 

 

 

 

improperly installed or missing. This affects the drive enclosure air flow and can

 

 

 

 

 

cause an over temperature condition. This problem was detected by the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit located in the drive enclosure identified

 

 

 

 

 

in the dencl_num field within the rack identified in the rack_num field. The

 

 

 

 

 

rack_num field will not be valid until a future release. The location of the affected

 

 

 

 

 

blower (1 or 2) is identified in the alarm_error_code.field.en field.

 

 

 

 

 

 

3404

88030d4c

6

d

4c

Storage Cell: %1 Event Code: %2 Description: Both drive enclosure blowers are

 

 

 

 

 

missing. This severely affects the drive enclosure air flow and can cause an over

 

 

 

 

 

temperature condition. The operational power supply(s) will automatically shut

 

 

 

 

 

down after a short period of time, thereby disabling the drive enclosure. This

 

 

 

 

 

condition remains active until either the problem is corrected, or the operational

 

 

 

 

 

power supply(s) shut down, whichever occurs first. This problem was detected by

 

 

 

 

 

the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. Note that this event is

 

 

 

 

 

preceded by a ‘drive enclosure blower is improperly installed or missing’ event

 

 

 

 

 

that identifies the location of the first missing blower. The location of the second

 

 

 

 

 

missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this

 

 

 

 

 

event.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

47