| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
3399 | 88030d47 | 6 | d | 47 | Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is not |
|
|
|
|
| operating properly. This could affect the drive enclosure air flow and cause an |
|
|
|
|
| over temperature condition. This problem was detected by the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit located in the drive enclosure identified in the |
|
|
|
|
| dencl_num field within the rack identified in the rack_num field.The rack_num |
|
|
|
|
| field will not be valid until a future release. The location of the affected blower (1 |
|
|
|
|
| or 2) is identified in the alarm_error_code.field.en field. The cause of the |
|
|
|
|
| improper operation is described by the content of the alarm_error_code.field.ec |
|
|
|
|
| field as follows: 1 = The blower is operating at a speed that is outside of the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit specified range, possibly because of a |
|
|
|
|
| bearing problem. 2 = The blower is operating at a speed that is significantly |
|
|
|
|
| outside of the Drive Enclosure Environmental Monitoring Unit specified range, |
|
|
|
|
| possibly because of a bearing problem. 3 = The blower has stopped. |
|
|
|
|
| NOTE: The other blower (if operational) now operates at high speed and is a |
|
|
|
|
| single point of failure. A single blower operating at high speed can provide |
|
|
|
|
| sufficient air flow to cool an enclosure and the elements for up to 100 hours. |
|
|
|
|
| However, operating an enclosure at temperatures approaching an overheating |
|
|
|
|
| threshold can damage elements and may reduce the MTBF of a specific element. |
|
|
|
|
| Compaq therefore recommends immediate replacement of the defective blower. |
|
|
|
|
| 4 = The power supply reported an internal blower error. |
|
|
|
|
|
|
3403 | 88030d4b | 6 | d | 4b | Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is |
|
|
|
|
| improperly installed or missing. This affects the drive enclosure air flow and can |
|
|
|
|
| cause an over temperature condition. This problem was detected by the Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit located in the drive enclosure identified |
|
|
|
|
| in the dencl_num field within the rack identified in the rack_num field. The |
|
|
|
|
| rack_num field will not be valid until a future release. The location of the affected |
|
|
|
|
| blower (1 or 2) is identified in the alarm_error_code.field.en field. |
|
|
|
|
|
|
3404 | 88030d4c | 6 | d | 4c | Storage Cell: %1 Event Code: %2 Description: Both drive enclosure blowers are |
|
|
|
|
| missing. This severely affects the drive enclosure air flow and can cause an over |
|
|
|
|
| temperature condition. The operational power supply(s) will automatically shut |
|
|
|
|
| down after a short period of time, thereby disabling the drive enclosure. This |
|
|
|
|
| condition remains active until either the problem is corrected, or the operational |
|
|
|
|
| power supply(s) shut down, whichever occurs first. This problem was detected by |
|
|
|
|
| the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. |
|
|
|
|
| The rack_num field will not be valid until a future release. Note that this event is |
|
|
|
|
| preceded by a ‘drive enclosure blower is improperly installed or missing’ event |
|
|
|
|
| that identifies the location of the first missing blower. The location of the second |
|
|
|
|
| missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this |
|
|
|
|
| event. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 47 |