HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

2340

88030924

2

9

24

Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’

 

 

 

 

 

blower assembly located within the HSV110 controller identified in the handle

 

 

 

 

 

field has transitioned from the NOT PRESENT to PRESENT state indicating that

 

 

 

 

 

the blower has been reinstalled. The secondary_id field contains the ‘2’ blower

 

 

 

 

 

assembly internal identifier value: 2. The value.ul1 field contains the new state of

 

 

 

 

 

the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of

 

 

 

 

 

the Blower Present flag: 0 (NOT PRESENT).

 

 

 

 

 

 

2341

88030925

6

9

25

Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower located within the

 

 

 

 

 

HSV110 controller identified in the handle field is running slower than the lowest

 

 

 

 

 

acceptable speed. The secondary_id field contains the ‘2’ blower assembly

 

 

 

 

 

internal identifier value: 2. The value.ul1 field contains the current speed of the

 

 

 

 

 

‘2’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘2’

 

 

 

 

 

blower.

 

 

 

 

 

 

2342

88030926

6

9

26

Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present

 

 

 

 

 

flag for the ‘1’ blower/power supply assembly located within the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned from the PRESENT to

 

 

 

 

 

NOT PRESENT state indicating that the blower/power supply has been removed.

 

 

 

 

 

The secondary_id field contains the ‘1’ blower/power supply assembly internal

 

 

 

 

 

identifier value: 1. The value.ul1 field contains the new state of the Blower/Power

 

 

 

 

 

Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state

 

 

 

 

 

of the Blower/Power Supply Present flag: 1 (PRESENT).

 

 

 

 

 

 

2343

88030927

2

9

27

Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present

 

 

 

 

 

flag for the ‘1’ blower/power supply assembly located within the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned from the NOT PRESENT

 

 

 

 

 

to PRESENT state indicating that the blower/power supply has been reinstalled.

 

 

 

 

 

The secondary_id field contains the ‘1’ blower/power supply assembly internal

 

 

 

 

 

identifier value: 1. The value.ul1 field contains the new state of the Blower/Power

 

 

 

 

 

Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the

 

 

 

 

 

Blower/Power Supply Present flag: 0 (NOT PRESENT).

 

 

 

 

 

 

2344

88030928

6

9

28

Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present

 

 

 

 

 

flag for the ‘2’ blower/power supply assembly located within the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned from the PRESENT to

 

 

 

 

 

NOT PRESENT state indicating that the blower/power supply has been removed.

 

 

 

 

 

The secondary_id field contains the ‘2’ blower/power supply assembly internal

 

 

 

 

 

identifier value: 2. The value.ul1 field contains the new state of the Blower/Power

 

 

 

 

 

Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state

 

 

 

 

 

of the Blower/Power Supply Present flag: 1 (PRESENT).

 

 

 

 

 

 

2345

88030929

2

9

29

Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present

 

 

 

 

 

flag for the ‘2’ blower/power supply assembly located within the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned from the NOT PRESENT

 

 

 

 

 

to PRESENT state indicating that the blower/power supply has been reinstalled.

 

 

 

 

 

The secondary_id field contains the ‘2’ blower/power supply assembly internal

 

 

 

 

 

identifier value: 2. The value.ul1 field contains the new state of the Blower/Power

 

 

 

 

 

Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the

 

 

 

 

 

Blower/Power Supply Present flag: 0 (NOT PRESENT).

 

 

 

 

 

 

2346

8803092a

6

9

2a

Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower/power supply

 

 

 

 

 

located within the HSV110 controller identified in the handle field is running

 

 

 

 

 

slower than the lowest acceptable speed. The secondary_id field contains the ‘1’

 

 

 

 

 

blower/power supply assembly internal identifier value: 1. The value.ul1 field

 

 

 

 

 

contains the current speed of the ‘1’ blower/power supply. The value.ul2 field

 

 

 

 

 

contains the lowest acceptable speed for the ‘1’ blower/power supply.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes