| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
2340 | 88030924 | 2 | 9 | 24 | Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’ |
|
|
|
|
| blower assembly located within the HSV110 controller identified in the handle |
|
|
|
|
| field has transitioned from the NOT PRESENT to PRESENT state indicating that |
|
|
|
|
| the blower has been reinstalled. The secondary_id field contains the ‘2’ blower |
|
|
|
|
| assembly internal identifier value: 2. The value.ul1 field contains the new state of |
|
|
|
|
| the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of |
|
|
|
|
| the Blower Present flag: 0 (NOT PRESENT). |
|
|
|
|
|
|
2341 | 88030925 | 6 | 9 | 25 | Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower located within the |
|
|
|
|
| HSV110 controller identified in the handle field is running slower than the lowest |
|
|
|
|
| acceptable speed. The secondary_id field contains the ‘2’ blower assembly |
|
|
|
|
| internal identifier value: 2. The value.ul1 field contains the current speed of the |
|
|
|
|
| ‘2’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘2’ |
|
|
|
|
| blower. |
|
|
|
|
|
|
2342 | 88030926 | 6 | 9 | 26 | Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present |
|
|
|
|
| flag for the ‘1’ blower/power supply assembly located within the HSV110 |
|
|
|
|
| controller identified in the handle field has transitioned from the PRESENT to |
|
|
|
|
| NOT PRESENT state indicating that the blower/power supply has been removed. |
|
|
|
|
| The secondary_id field contains the ‘1’ blower/power supply assembly internal |
|
|
|
|
| identifier value: 1. The value.ul1 field contains the new state of the Blower/Power |
|
|
|
|
| Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state |
|
|
|
|
| of the Blower/Power Supply Present flag: 1 (PRESENT). |
|
|
|
|
|
|
2343 | 88030927 | 2 | 9 | 27 | Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present |
|
|
|
|
| flag for the ‘1’ blower/power supply assembly located within the HSV110 |
|
|
|
|
| controller identified in the handle field has transitioned from the NOT PRESENT |
|
|
|
|
| to PRESENT state indicating that the blower/power supply has been reinstalled. |
|
|
|
|
| The secondary_id field contains the ‘1’ blower/power supply assembly internal |
|
|
|
|
| identifier value: 1. The value.ul1 field contains the new state of the Blower/Power |
|
|
|
|
| Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the |
|
|
|
|
| Blower/Power Supply Present flag: 0 (NOT PRESENT). |
|
|
|
|
|
|
2344 | 88030928 | 6 | 9 | 28 | Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present |
|
|
|
|
| flag for the ‘2’ blower/power supply assembly located within the HSV110 |
|
|
|
|
| controller identified in the handle field has transitioned from the PRESENT to |
|
|
|
|
| NOT PRESENT state indicating that the blower/power supply has been removed. |
|
|
|
|
| The secondary_id field contains the ‘2’ blower/power supply assembly internal |
|
|
|
|
| identifier value: 2. The value.ul1 field contains the new state of the Blower/Power |
|
|
|
|
| Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state |
|
|
|
|
| of the Blower/Power Supply Present flag: 1 (PRESENT). |
|
|
|
|
|
|
2345 | 88030929 | 2 | 9 | 29 | Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present |
|
|
|
|
| flag for the ‘2’ blower/power supply assembly located within the HSV110 |
|
|
|
|
| controller identified in the handle field has transitioned from the NOT PRESENT |
|
|
|
|
| to PRESENT state indicating that the blower/power supply has been reinstalled. |
|
|
|
|
| The secondary_id field contains the ‘2’ blower/power supply assembly internal |
|
|
|
|
| identifier value: 2. The value.ul1 field contains the new state of the Blower/Power |
|
|
|
|
| Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the |
|
|
|
|
| Blower/Power Supply Present flag: 0 (NOT PRESENT). |
|
|
|
|
|
|
2346 | 8803092a | 6 | 9 | 2a | Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower/power supply |
|
|
|
|
| located within the HSV110 controller identified in the handle field is running |
|
|
|
|
| slower than the lowest acceptable speed. The secondary_id field contains the ‘1’ |
|
|
|
|
| blower/power supply assembly internal identifier value: 1. The value.ul1 field |
|
|
|
|
| contains the current speed of the ‘1’ blower/power supply. The value.ul2 field |
|
|
|
|
| contains the lowest acceptable speed for the ‘1’ blower/power supply. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 37 |