HSV Element Manager Event Codes

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

2311

88030907

2

9

7

Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel

 

 

 

 

 

port identified in the attribute.value.str field and located on the rear panel of the

 

 

 

 

 

HSV110 controller identified in the handle field has transitioned to the NORMAL

 

 

 

 

 

state. The attribute.type field contains the value 4. The value.ul1 field contains the

 

 

 

 

 

new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED).

 

 

 

 

 

Note that the HSV110 controller’s internal identity of the affected Fibre Channel

 

 

 

 

 

port is contained in the secondary_id field.

 

 

 

 

 

 

2312

88030908

3

9

8

Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level

 

 

 

 

 

threshold has been reached for the Disk Group identified in the handle field.

 

 

 

 

 

 

2313

88030909

2

9

9

Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of

 

 

 

 

 

the Volume identified in the handle field has transitioned to the SUFFICIENT state.

 

 

 

 

 

The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field

 

 

 

 

 

contains the old state: 1 (INSUFFICIENT).

 

 

 

 

 

 

2314

8803090a

2

9

a

Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the

 

 

 

 

 

Logical Disk identified in the handle field has transitioned to the NORMAL state.

 

 

 

 

 

The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field

 

 

 

 

 

contains the old state: 1 (DATA LOST).

 

 

 

 

 

 

2316

8803090c

2

9

c

Storage Cell: %1 Event Code: %2 Description: The Snapclone Logical Disk

 

 

 

 

 

identified in the handle field has completed the unsharing operation.

 

 

 

 

 

 

2317

8803090d

2

9

d

Storage Cell: %1 Event Code: %2 Description: The state of the Quorum Disk flag

 

 

 

 

 

for the Volume identified in the handle field has changed. The value.ul1 field

 

 

 

 

 

contains the new state of the Quorum Disk flag. The value.ul2 field contains the

 

 

 

 

 

old state of the Quorum Disk flag. The state values that may be found in the

 

 

 

 

 

value.ul1 and value.ul2 fields are as follows: 0 = FALSE 1 = TRUE

 

 

 

 

 

 

2318

8803090e

3

9

e

Storage Cell: %1 Event Code: %2 Description: The temperature trip point for a

 

 

 

 

 

temperature sensor located within the HSV110 controller identified in the handle

 

 

 

 

 

field has been reached.

 

 

 

 

 

 

2319

8803090f

3

9

f

Storage Cell: %1 Event Code: %2 Description: A temperature sensor located

 

 

 

 

 

within the HSV110 controller identified in the handle field is approaching its trip

 

 

 

 

 

point. The value.ul1 field contains the current temperature reading from that

 

 

 

 

 

sensor in Celsius. The secondary_id field contains the temperature trip point in

 

 

 

 

 

Celsius.

 

 

 

 

 

 

2321

88030911

2

9

11

Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’

 

 

 

 

 

blower assembly located within the HSV110 controller identified in the handle

 

 

 

 

 

field has transitioned from the NOT PRESENT to PRESENT state indicating that

 

 

 

 

 

the blower has been reinstalled. The secondary_id field contains the ‘1’ blower

 

 

 

 

 

assembly internal identifier value: 1. The value.ul1 field contains the new state of

 

 

 

 

 

the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of

 

 

 

 

 

the Blower Present flag: 0 (NOT PRESENT).

 

 

 

 

 

 

2322

88030912

6

9

12

Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower located within the

 

 

 

 

 

HSV110 controller identified in the handle field is running slower than the lowest

 

 

 

 

 

acceptable speed. The secondary_id field contains the ‘1’ blower assembly

 

 

 

 

 

internal identifier value: 1. The value.ul1 field contains the current speed of the

 

 

 

 

 

‘1’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘1’

 

 

 

 

 

blower.

 

 

 

 

 

 

2323

88030913

2

9

13

Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors

 

 

 

 

 

located within the HSV110 controller identified in the handle field has reported a

 

 

 

 

 

voltage that is out of range. The value.ul1 field contains the out of range voltage

 

 

 

 

 

value. The secondary_id field contains the specific voltage threshold value (i.e.,

 

 

 

 

 

12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in

 

 

 

 

 

millivolts--e.g.,12.5V is expressed as 12500.

 

 

 

 

 

 

34

Storage Management Appliance Software Event Code Definitions Application Notes