HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
2311 | 88030907 | 2 | 9 | 7 | Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel |
|
|
|
|
| port identified in the attribute.value.str field and located on the rear panel of the |
|
|
|
|
| HSV110 controller identified in the handle field has transitioned to the NORMAL |
|
|
|
|
| state. The attribute.type field contains the value 4. The value.ul1 field contains the |
|
|
|
|
| new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED). |
|
|
|
|
| Note that the HSV110 controller’s internal identity of the affected Fibre Channel |
|
|
|
|
| port is contained in the secondary_id field. |
|
|
|
|
|
|
2312 | 88030908 | 3 | 9 | 8 | Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level |
|
|
|
|
| threshold has been reached for the Disk Group identified in the handle field. |
|
|
|
|
|
|
2313 | 88030909 | 2 | 9 | 9 | Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of |
|
|
|
|
| the Volume identified in the handle field has transitioned to the SUFFICIENT state. |
|
|
|
|
| The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field |
|
|
|
|
| contains the old state: 1 (INSUFFICIENT). |
|
|
|
|
|
|
2314 | 8803090a | 2 | 9 | a | Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the |
|
|
|
|
| Logical Disk identified in the handle field has transitioned to the NORMAL state. |
|
|
|
|
| The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field |
|
|
|
|
| contains the old state: 1 (DATA LOST). |
|
|
|
|
|
|
2316 | 8803090c | 2 | 9 | c | Storage Cell: %1 Event Code: %2 Description: The Snapclone Logical Disk |
|
|
|
|
| identified in the handle field has completed the unsharing operation. |
|
|
|
|
|
|
2317 | 8803090d | 2 | 9 | d | Storage Cell: %1 Event Code: %2 Description: The state of the Quorum Disk flag |
|
|
|
|
| for the Volume identified in the handle field has changed. The value.ul1 field |
|
|
|
|
| contains the new state of the Quorum Disk flag. The value.ul2 field contains the |
|
|
|
|
| old state of the Quorum Disk flag. The state values that may be found in the |
|
|
|
|
| value.ul1 and value.ul2 fields are as follows: 0 = FALSE 1 = TRUE |
|
|
|
|
|
|
2318 | 8803090e | 3 | 9 | e | Storage Cell: %1 Event Code: %2 Description: The temperature trip point for a |
|
|
|
|
| temperature sensor located within the HSV110 controller identified in the handle |
|
|
|
|
| field has been reached. |
|
|
|
|
|
|
2319 | 8803090f | 3 | 9 | f | Storage Cell: %1 Event Code: %2 Description: A temperature sensor located |
|
|
|
|
| within the HSV110 controller identified in the handle field is approaching its trip |
|
|
|
|
| point. The value.ul1 field contains the current temperature reading from that |
|
|
|
|
| sensor in Celsius. The secondary_id field contains the temperature trip point in |
|
|
|
|
| Celsius. |
|
|
|
|
|
|
2321 | 88030911 | 2 | 9 | 11 | Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’ |
|
|
|
|
| blower assembly located within the HSV110 controller identified in the handle |
|
|
|
|
| field has transitioned from the NOT PRESENT to PRESENT state indicating that |
|
|
|
|
| the blower has been reinstalled. The secondary_id field contains the ‘1’ blower |
|
|
|
|
| assembly internal identifier value: 1. The value.ul1 field contains the new state of |
|
|
|
|
| the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of |
|
|
|
|
| the Blower Present flag: 0 (NOT PRESENT). |
|
|
|
|
|
|
2322 | 88030912 | 6 | 9 | 12 | Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower located within the |
|
|
|
|
| HSV110 controller identified in the handle field is running slower than the lowest |
|
|
|
|
| acceptable speed. The secondary_id field contains the ‘1’ blower assembly |
|
|
|
|
| internal identifier value: 1. The value.ul1 field contains the current speed of the |
|
|
|
|
| ‘1’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘1’ |
|
|
|
|
| blower. |
|
|
|
|
|
|
2323 | 88030913 | 2 | 9 | 13 | Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors |
|
|
|
|
| located within the HSV110 controller identified in the handle field has reported a |
|
|
|
|
| voltage that is out of range. The value.ul1 field contains the out of range voltage |
|
|
|
|
| value. The secondary_id field contains the specific voltage threshold value (i.e., |
|
|
|
|
| 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in |
|
|
|
|
| |
|
|
|
|
|
|
34 | Storage Management Appliance Software Event Code Definitions Application Notes |