HSV Element Manager Event Codes

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

Event

Event

Sev-

SWC

Evt.

 

Description

ID

Code

erity

ID

No.

 

771

88030303

2

3

3

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller has

 

 

 

 

 

begun booting.

 

 

 

 

 

 

 

 

772

88030304

2

3

4

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller, identified

 

 

 

 

 

in the node_name field, has finished the process of bringing the Storage System,

 

 

 

 

 

identified in the cell_tag fields, online.

 

 

 

 

 

 

 

773

88030305

2

3

5

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller identified

 

 

 

 

 

in the node_name field has been joined into the Storage System.

 

 

 

 

 

 

 

774

88030306

2

3

6

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller identified

 

 

 

 

 

in the node_name field has been ousted from the Storage System, identified in

 

 

 

 

 

the cell_tag fields

 

 

 

 

 

 

 

 

775

88030307

2

3

7

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller identified

 

 

 

 

 

in the node_name field is now the Storage System master, identified in the

 

 

 

 

 

cell_tag fields, master

 

 

 

 

 

 

 

776

88030308

2

3

8

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller identified

 

 

 

 

 

in the node_name field has been brought into the Storage System, identified in

 

 

 

 

 

the cell_tag fields.

 

 

 

 

 

 

1024

88030400

6

4

0

Storage Cell: %1 Event Code: %2 Description: HSV110 controller operation was

 

 

 

 

 

terminated due to an unrecoverable event detected by either software or

 

 

 

 

 

hardware or due to an action initiated via the Storage System Management

 

 

 

 

 

Interface.

 

 

 

 

 

 

 

 

1025

88030401

6

4

1

Storage Cell: %1

Event Code: %2 Description: The HSV110 controller identified

 

 

 

 

 

in the lter.terminating_ctrlr field sent a last gasp message prior to terminating

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

1026

88030402

6

4

2

Storage Cell: %1

Event Code: %2 Description: A machine check occurred while

 

 

 

 

 

a termination event was being processed. The post-termination operation being

 

 

 

 

 

performed at the time the event occurred can be derived from the

 

 

 

 

 

lter.reuea_index field.

 

 

 

 

 

Note: The lteihd and lter fields may not describe the event that caused the

 

 

 

 

 

HSV110 controller to terminate operation depending on how far termination

 

 

 

 

 

processing got before the machine check occurred.

 

 

 

 

 

 

 

22