HSV Element Manager Event Codes

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3459

88030d83

6

d

83

Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit has experienced a hardware failure. This problem was detected

 

 

 

 

 

by the Drive Enclosure Environmental Monitoring Unit located in the drive

 

 

 

 

 

enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element.

 

 

 

 

 

 

3461

88030d85

3

d

85

Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply

 

 

 

 

 

failed to respond to a shut down command. This problem was detected by the

 

 

 

 

 

Drive Enclosure Environmental Monitoring Unit located in the drive enclosure

 

 

 

 

 

identified in the dencl_num field within the rack identified in the rack_num field.

 

 

 

 

 

The rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit is the affected element.

 

 

 

 

 

 

3469

88030d8d

6

d

8d

Storage Cell: %1 Event Code: %2 Description: A drive enclosure transceiver

 

 

 

 

 

error has been detected. This problem was detected by the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit located in the drive enclosure identified in the

 

 

 

 

 

dencl_num field within the rack identified in the rack_num field. The rack_num

 

 

 

 

 

field will not be valid until a future release. The location of the transceiver (1

 

 

 

 

 

through 4) is identified in the alarm_error_code.field.en field as follows: 1 =

 

 

 

 

 

Transceiver 01 2 = Transceiver 02 3 = Transceiver 03 4 = Transceiver 04 The

 

 

 

 

 

transceiver error condition is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 1 = The transceivers on this link are

 

 

 

 

 

not the same type or they are incompatible with the drive enclosure I/O module.

 

 

 

 

 

This error prevents the controller from establishing a link with the enclosure drives

 

 

 

 

 

and eliminates the enclosure dual-loop capability. 2 = The transceiver can no

 

 

 

 

 

longer detect a data signal. This error prevents the controller from transferring

 

 

 

 

 

data on a loop and eliminates the enclosure dual-loop capability. 3 = The

 

 

 

 

 

system has detected an FC-AL bus fault involving a transceiver. This error prevents

 

 

 

 

 

the controller from transferring data on a loop and eliminates the enclosure

 

 

 

 

 

dual-loop capability.

 

 

 

 

 

 

3489

88030da1

6

d

a1

Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply

 

 

 

 

 

voltage sensor out of range condition has been reported. This problem was

 

 

 

 

 

detected by the Drive Enclosure Environmental Monitoring Unit located in the

 

 

 

 

 

drive enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

location of the voltage sensor (1 through 4) is identified in the

 

 

 

 

 

alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =

 

 

 

 

 

Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12

 

 

 

 

 

VDC The voltage sensor out of range condition is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 1 = The element voltage is

 

 

 

 

 

approaching, but has not reached, the high voltage CRITICAL threshold.

 

 

 

 

 

Continued operation under these conditions may result in a CRITICAL condition.

 

 

 

 

 

2 = The element voltage is above the high voltage CRITICAL threshold. 3 = The

 

 

 

 

 

element voltage is approaching, but h as not reached, the low voltage CRITICAL

 

 

 

 

 

threshold. Continued operation under these conditions may result in a CRITICAL

 

 

 

 

 

condition. 4 = The element voltage has reached the low voltage CRITICAL

 

 

 

 

 

threshold.

 

 

 

 

 

 

50