HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1560 | 88030618 | 2 | 6 | 18 | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit has begun updating its code. Do not power down this drive |
|
|
|
|
| enclosure until the code update has completed. The identity of the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the device field. The Fibre |
|
|
|
|
| Channel port used to communicate with the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal |
|
|
|
|
| Fibre Channel port number used to communicate with the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the port field. The location of the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and |
|
|
|
|
| dencl_num fields. The rack_num field will not be valid until a future release. |
|
|
|
|
| Note that in this case the content of the fed_class, alpa, and num_times fields are |
|
|
|
|
| undefined. |
|
|
|
|
|
|
1561 | 88030619 | 2 | 6 | 19 | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit has completed updating its code. It is now safe to power down |
|
|
|
|
| this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring |
|
|
|
|
| Unit is contained in the device field. The Fibre Channel port used to |
|
|
|
|
| communicate with the Drive Enclosure Environmental Monitoring Unit is |
|
|
|
|
| contained in the cerp_id field. The HSV110 controller internal Fibre Channel |
|
|
|
|
| port number used to communicate with the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is contained in the port field. The location of the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the rack_num and dencl_num |
|
|
|
|
| fields. The rack_num field will not be valid until a future release. Note that in this |
|
|
|
|
| case the content of the fed_class, alpa, and num_times fields are undefined. |
|
|
|
|
|
|
1562 | 8803061a | 6 | 6 | 1a | Storage Cell: %1 Event Code: %2 Description: A physical disk drive has |
|
|
|
|
| exceeded its soft error threshold. The identity of the physical disk drive is |
|
|
|
|
| contained in the device field. The Fibre Channel port used to communicate with |
|
|
|
|
| the physical disk drive is contained in the cerp_id field. The HSV110 controller |
|
|
|
|
| internal Fibre Channel port number used to communicate with the physical disk |
|
|
|
|
| drive is contained in the port field. The arbitrated loop physical address of the |
|
|
|
|
| physical disk drive is contained in the al_pa field. If the bay field contains a |
|
|
|
|
| value other than zero, the location of the physical disk drive is contained in the |
|
|
|
|
| rack_num, dencl_num, and bay fields. If the bay field contains a zero, the |
|
|
|
|
| location of the physical disk drive is unknown and the content of the rack_num |
|
|
|
|
| and dencl_num fields is undefined. The rack_num field will not be valid until a |
|
|
|
|
| future release. Note that in this case the content of the fed_class, cdb, and |
|
|
|
|
| sense_data fields are undefined. |
|
|
|
|
|
|
1563 | 8803061b | 2 | 6 | 1b | Storage Cell: %1 Event Code: %2 Description: A HSV110 controller now has an |
|
|
|
|
| address on the enclosure address bus. The HSV110 controller location has been |
|
|
|
|
| identified. The location of the HSV110 controller is contained in the rack_num |
|
|
|
|
| and dencl_num fields. The rack_num field will not be valid until a future release. |
|
|
|
|
| Note that in this case the content of the bay, fed_class, alpa, cerp_id, port, and |
|
|
|
|
| num_times fields are undefined. |
|
|
|
|
|
|
32 | Storage Management Appliance Software Event Code Definitions Application Notes |