HSV Element Manager Event Codes

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3332

88030d04

6

d

4

Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is

 

 

 

 

 

capable of operating at the loop link rate established by the drive enclosure I/O

 

 

 

 

 

module was found to be running at a different rate. This problem was detected

 

 

 

 

 

by the Drive Enclosure Environmental Monitoring Unit located in the drive

 

 

 

 

 

enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

affected physical disk drive is installed in the drive enclosure bay identified in the

 

 

 

 

 

alarm_error_code.field.en field. The Fibre Channel loop on which the problem

 

 

 

 

 

was detected is identified by the content of the alarm_error_code.field.ec field as

 

 

 

 

 

follows: 4 = loop A 5 = loop B

 

 

 

 

 

 

3379

88030d33

3

d

33

Storage Cell: %1 Event Code: %2 Description: The AC input to a drive enclosure

 

 

 

 

 

power supply has been lost. This makes the remaining power supply a single

 

 

 

 

 

point of failure. This problem was detected by the Drive Enclosure Environmental

 

 

 

 

 

Monitoring Unit located in the drive enclosure identified in the dencl_num field

 

 

 

 

 

within the rack identified in the rack_num field. The rack_num field will not be

 

 

 

 

 

valid until a future release. The location of the affected power supply (1 or 2) is

 

 

 

 

 

identified in the alarm_error_code.field.en field.

 

 

 

 

 

 

3380

88030d34

6

d

34

Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply is

 

 

 

 

 

improperly installed or missing. This could affect the drive enclosure air flow and

 

 

 

 

 

cause an over temperature condition. The operational power supply will

 

 

 

 

 

automatically shut down after a short period of time, thereby disabling the drive

 

 

 

 

 

enclosure. This condition remains active until either the problem is corrected, or

 

 

 

 

 

the operational power supply shuts down, whichever occurs first. This problem

 

 

 

 

 

was detected by the Drive Enclosure Environmental Monitoring Unit located in the

 

 

 

 

 

drive enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

location of the affected power supply (1 or 2) is identified in the

 

 

 

 

 

alarm_error_code.field.en field.

 

 

 

 

 

 

3381

88030d35

6

d

35

Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply

 

 

 

 

 

component has failed. This problem was detected by the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit located in the drive enclosure identified in the

 

 

 

 

 

dencl_num field within the rack identified in the rack_num field. The rack_num

 

 

 

 

 

field will not be valid until a future release. The location of the affected power

 

 

 

 

 

supply (1 or 2) is identified in the alarm_error_code.field.en field.

 

 

 

 

 

 