HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
3332 | 88030d04 | 6 | d | 4 | Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is |
|
|
|
|
| capable of operating at the loop link rate established by the drive enclosure I/O |
|
|
|
|
| module was found to be running at a different rate. This problem was detected |
|
|
|
|
| by the Drive Enclosure Environmental Monitoring Unit located in the drive |
|
|
|
|
| enclosure identified in the dencl_num field within the rack identified in the |
|
|
|
|
| rack_num field. The rack_num field will not be valid until a future release. The |
|
|
|
|
| affected physical disk drive is installed in the drive enclosure bay identified in the |
|
|
|
|
| alarm_error_code.field.en field. The Fibre Channel loop on which the problem |
|
|
|
|
| was detected is identified by the content of the alarm_error_code.field.ec field as |
|
|
|
|
| follows: 4 = loop A 5 = loop B |
|
|
|
|
|
|
3379 | 88030d33 | 3 | d | 33 | Storage Cell: %1 Event Code: %2 Description: The AC input to a drive enclosure |
|
|
|
|
| power supply has been lost. This makes the remaining power supply a single |
|
|
|
|
| point of failure. This problem was detected by the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit located in the drive enclosure identified in the dencl_num field |
|
|
|
|
| within the rack identified in the rack_num field. The rack_num field will not be |
|
|
|
|
| valid until a future release. The location of the affected power supply (1 or 2) is |
|
|
|
|
| identified in the alarm_error_code.field.en field. |
|
|
|
|
|
|
3380 | 88030d34 | 6 | d | 34 | Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply is |
|
|
|
|
| improperly installed or missing. This could affect the drive enclosure air flow and |
|
|
|
|
| cause an over temperature condition. The operational power supply will |
|
|
|
|
| automatically shut down after a short period of time, thereby disabling the drive |
|
|
|
|
| enclosure. This condition remains active until either the problem is corrected, or |
|
|
|
|
| the operational power supply shuts down, whichever occurs first. This problem |
|
|
|
|
| was detected by the Drive Enclosure Environmental Monitoring Unit located in the |
|
|
|
|
| drive enclosure identified in the dencl_num field within the rack identified in the |
|
|
|
|
| rack_num field. The rack_num field will not be valid until a future release. The |
|
|
|
|
| location of the affected power supply (1 or 2) is identified in the |
|
|
|
|
| alarm_error_code.field.en field. |
|
|
|
|
|
|
3381 | 88030d35 | 6 | d | 35 | Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply |
|
|
|
|
| component has failed. This problem was detected by the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit located in the drive enclosure identified in the |
|
|
|
|
| dencl_num field within the rack identified in the rack_num field. The rack_num |
|
|
|
|
| field will not be valid until a future release. The location of the affected power |
|
|
|
|
| supply (1 or 2) is identified in the alarm_error_code.field.en field. |
|
|
|
|
|
|
46 | Storage Management Appliance Software Event Code Definitions Application Notes |