HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
1550 | 8803060e | 6 | 6 | e | Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit requested a code update but the code update could not be |
|
|
|
|
| found, so the update was not performed. The identity of the affected Drive |
|
|
|
|
| Enclosure Environmental Monitoring Unit is contained in the device field. The |
|
|
|
|
| Fibre Channel port used to communicate with the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal |
|
|
|
|
| Fibre Channel port number used to communicate with the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the port field. The location of the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and |
|
|
|
|
| dencl_num fields. The rack_num field will not be valid until a future release. |
|
|
|
|
| Note that in this case the content of the al_pa, bay, fed_class and num_times |
|
|
|
|
| field is undefined. |
|
|
|
|
|
|
1551 | 8803060f | 6 | 6 | f | Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is able to communicate with a physical disk drive |
|
|
|
|
| but this HSV110 controller is unable to communicate with that physical disk drive |
|
|
|
|
| on the Fibre Channel bus. The identity of the Drive Enclosure Environmental |
|
|
|
|
| Monitoring Unit is contained in the device field. The Fibre Channel port used to |
|
|
|
|
| communicate with the physical disk drive is contained in the cerp_id field. The |
|
|
|
|
| HSV110 controller internal Fibre Channel port number used to communicate with |
|
|
|
|
| the physical disk drive is contained in the port field. The location of the physical |
|
|
|
|
| disk drive is contained in the rack_num, dencl_num, and bay fields. The |
|
|
|
|
| rack_num field will not be valid until a future release. Note that in this case the |
|
|
|
|
| content of the al_pa, fed_class and num_times fields is undefined. |
|
|
|
|
|
|
1552 | 88030610 | 6 | 6 | 10 | Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is unable to communicate with this HSV110 |
|
|
|
|
| controller. The Drive Enclosure Environmental Monitoring Unit has either stopped |
|
|
|
|
| communicating with the HSV110 controller, or is not connected to the rack. If the |
|
|
|
|
| Drive Enclosure Environmental Monitoring Unit is not connected to the rack, then |
|
|
|
|
| the location of the Drive Enclosure Environmental Monitoring Unit is unknown. If |
|
|
|
|
| the bay field contains a value other than zero, the identity of the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the device field. If the bay field |
|
|
|
|
| contains a zero, the content of the device field is undefined. The Fibre Channel |
|
|
|
|
| port used to communicate with the Drive Enclosure Environmental Monitoring |
|
|
|
|
| Unit is contained in the cerp_id field. The HSV110 controller internal Fibre |
|
|
|
|
| Channel port number used to communicate with the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the port field. If the bay field |
|
|
|
|
| contains a value other than zero, the location of the Dr ive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is contained in the rack_num and dencl_num |
|
|
|
|
| fields. If the bay field contains a zero, the location of the Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit is unknown and the content of the rack_num and |
|
|
|
|
| dencl_num fields is undefined. The rack_num field will not be valid until a future |
|
|
|
|
| release. Note that in this case the content of the al_pa, fed_class and num_times |
|
|
|
|
| fields is undefined. |
|
|
|
|
|
|
30 | Storage Management Appliance Software Event Code Definitions Application Notes |