HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

2324

88030914

6

9

14

Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified

 

 

 

 

 

in the handle field has transitioned to the FAILED state. The value.ul1 field

 

 

 

 

 

contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The

 

 

 

 

 

state values that may be found in the value.ul2 fields are as follows: 1 = Normal

 

 

 

 

 

2 = Migrating 3 = Missing 4 = Reconstructing 5 = Completing 6 = Reverting

 

 

 

 

 

 

2325

88030915

6

9

15

Storage Cell: %1 Event Code: %2 Description: The state of the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned to the FAILED state. The

 

 

 

 

 

value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the

 

 

 

 

 

old state: 1 (NORMAL).

 

 

 

 

 

 

2327

88030917

6

9

17

Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for

 

 

 

 

 

battery assembly ‘1’ located within the HSV110 controller identified in the

 

 

 

 

 

handle field has changed from PRESENT to NOT PRESENT indicating that the

 

 

 

 

 

battery assembly was removed. The secondary_id field contains the battery

 

 

 

 

 

assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state

 

 

 

 

 

of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old

 

 

 

 

 

state of the Battery Present flag: 1 (PRESENT).

 

 

 

 

 

 

2328

88030918

2

9

18

Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery

 

 

 

 

 

assembly ‘1’ located within the HSV110 controller identified in the handle field

 

 

 

 

 

has transitioned from the NOT IN USE to IN USE state indicating that the battery

 

 

 

 

 

assembly is functioning properly. The secondary_id field contains the battery

 

 

 

 

 

assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state

 

 

 

 

 

of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of

 

 

 

 

 

the Battery In Use flag: 0 (NOT IN USE).

 

 

 

 

 

 

2329

88030919

2

9

19

Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors

 

 

 

 

 

located within the HSV110 controller identified in the handle field has reported a

 

 

 

 

 

voltage that indicates that a voltage that was previously out of range has returned

 

 

 

 

 

to the normal range. The value.ul1 field contains the normal range voltage

 

 

 

 

 

value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V,

 

 

 

 

 

3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g.,

 

 

 

 

 

12.5V is expressed as 12500.

 

 

 

 

 

 

2330

8803091a

3

9

1a

Storage Cell: %1 Event Code: %2 Description: The battery assembly voltage

 

 

 

 

 

regulator located within the HSV110 controller identified in the handle field is

 

 

 

 

 

offline.

 

 

 

 

 

 

2331

8803091b

2

9

1b

Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group

 

 

 

 

 

identified in the handle field has transitioned to the NORMAL state. The value.ul1

 

 

 

 

 

field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field

 

 

 

 

 

contains the old Disk Group state. The state values that may be found in the

 

 

 

 

 

value.ul2 field are as follows: 2 = Disk Group with no redundancy is inoperative

 

 

 

 

 

3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with

 

 

 

 

 

mirrored redundancy is inoperative 5 = Disk Group with no redundancy is

 

 

 

 

 

inoperative, marked for re-use 6 = Disk Group with parity redundancy is

 

 

 

 

 

inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is

 

 

 

 

 

inoperative, marked for re-use

 

 

 

 

 

 

2332

8803091c

2

9

1c

Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level for

 

 

 

 

 

the Disk Group identified in the handle field has returned to the normal range.

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

35