HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

 

Description

ID

Code

erity

ID

No.

 

1564

8803061c

3

6

1c

Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent

 

 

 

 

 

to a physical disk drive has timed out. The identity of the physical disk drive is

 

 

 

 

 

contained in the device field. The Fibre Channel port used to communicate with

 

 

 

 

 

the physical disk drive is contained in the cerp_id field. The HSV110 controller

 

 

 

 

 

internal Fibre Channel port number used to communicate with the physical disk

 

 

 

 

 

drive is contained in the port field. The arbitrated loop physical address of the

 

 

 

 

 

physical disk drive is contained in the al_pa field. If the bay field contains a

 

 

 

 

 

value other than zero, the location of the physical disk drive is contained in the

 

 

 

 

 

rack_num, dencl_num, and bay fields. If the bay field contains a zero, the

 

 

 

 

 

location of the physical disk drive is unknown and the content of the rack_num

 

 

 

 

 

and dencl_num fields is undefined. The rack_num field will not be valid until a

 

 

 

 

 

future release. The Fibre Channel Exchange Descriptor class is contained in the

 

 

 

 

 

fed_class field. The command issued to the physical disk drive is contained in the

 

 

 

 

 

cmd field. Note

that in this case the content of the error field is undefined.

 

 

 

 

 

 

 

2305

88030901

2

9

1

Storage Cell: %1

Event Code: %2 Description: The state of the Physical Disk

 

 

 

 

 

Drive identified in the handle field has transitioned to the NORMAL state. The

 

 

 

 

 

value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains

 

 

 

 

 

the old state. The state values that may be in the value.ul2 field are as follows: 2

 

 

 

 

 

= Degraded 3 = Failed 4 = Not present

 

 

 

 

 

 

 

2306

88030902

2

9

2

Storage Cell: %1

Event Code: %2 Description: The state of the Volume identified

 

 

 

 

 

in the handle field has changed. The value.ul1 field contains the new state. The

 

 

 

 

 

value.ul2 field contains the old state. The state values that may be found in the

 

 

 

 

 

value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Migrating 3 =

 

 

 

 

 

Missing 4 = Reconstructing 5 = Completing 6 = Reverting 7 = Failed

 

 

 

 

 

 

 

2307

88030903

2

9

3

Storage Cell: %1

Event Code: %2 Description: The state of The internal Logical

 

 

 

 

 

Disk associated with the Virtual Disk identified in the handle field has changed.

 

 

 

 

 

The value.ul1 field contains the new state. The value.ul2 field contains the old

 

 

 

 

 

state. The state values that may be found in the value.ul1 and value.ul2 fields are

 

 

 

 

 

as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost,

 

 

 

 

 

restore in progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in

 

 

 

 

 

progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion

 

 

 

 

 

in progress 9 = Capacity change in progress 10 = Inoperative due to data lost

 

 

 

 

 

 

 

2308

88030904

2

9

4

Storage Cell: %1

Event Code: %2 Description: The state of the HSV110

 

 

 

 

 

controller identified in the handle field has transitioned to the NORMAL state. The

 

 

 

 

 

value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains

 

 

 

 

 

the old state: 3 (FAILED).

 

 

 

 

 

 

 

2309

88030905

2

9

5

Storage Cell: %1

Event Code: %2 Description: The state of a battery assembly

 

 

 

 

 

within the HSV110 controller identified in the handle field has changed. The

 

 

 

 

 

value.ul1 field contains the new state. The value.ul2 field contains the old state.

 

 

 

 

 

The state values that may be found in the value.ul1 and value.ul2 fields are as

 

 

 

 

 

follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 = Battery

 

 

 

 

 

System Hold-up Time is greater than 0 and less than 96 hours 5 = Battery System

 

 

 

 

 

Hold-up Time is zero hours

 

 

 

 

 

 

 

2310

88030906

6

9

6

Storage Cell: %1

Event Code: %2 Description: The state of the Volume identified

 

 

 

 

 

in the handle field has transitioned to the MISSING state. The value.ul1 field

 

 

 

 

 

contains the new state: 3 (MISSING). The value.ul2 field contains the old state.

 

 

 

 

 

The state values that may be found in the value.ul2 field are as follows: 1 =

 

 

 

 

 

Normal 2 = Migrating 4 = Reconstructing 5 = Completing 6 = Reverting 7 =

 

 

 

 

 

Failed

 

 

 

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes

33