HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
2417 | 88030971 | 2 | 9 | 71 | Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified |
|
|
|
|
| in the handle field received a request to shutdown. The old_attr.type field and the |
|
|
|
|
| new_attr.type fields contain the value 1. The old_attr.value.u32[0] field indicates |
|
|
|
|
| the type of restart that was requested as follows: 0 = None |
|
|
|
|
| Regular |
|
|
|
|
| normal operation 2 = Fast |
|
|
|
|
| manner that has little or no impact on host system connectivity The |
|
|
|
|
| old_attr.value.u32[1] field indicates whether the other HSV110 controller of the |
|
|
|
|
| pair was requested to remain operational or to also shutdown as follows: 0 = |
|
|
|
|
| Remain operational 1 = Coupled shutdown The old_attr.value.u32[2] field |
|
|
|
|
| indicates whether the HSV110 controller was requested to remain in the power |
|
|
|
|
| on state or power itself off as follows: 0 = Remain in the power on state 1 = |
|
|
|
|
| Power itself off The old_attr.value.u32[3] field value indicates whether the |
|
|
|
|
| Physical Disk Drive enclosure(s) was requested to remain in the power on state or |
|
|
|
|
| to be powered off as follows: 0 = Remain in the power on state 1 = Powered off |
|
|
|
|
| The old_attr.value.u32[4] field value indicates whether the battery assemblies |
|
|
|
|
| located within the HSV110 controller were requested to be enabled or disabled |
|
|
|
|
| as follows: 0 = Enabled 1 = Disabled The old_attr.value.u32[5] field contains the |
|
|
|
|
| number of seconds the shutdown operation was requested to be delayed. |
|
|
|
|
|
|
2418 | 88030972 | 2 | 9 | 72 | Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified |
|
|
|
|
| in the handle field has completed its shutdown preparations. The old_attr.type |
|
|
|
|
| field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] |
|
|
|
|
| field value indicates the result of the HSV110 controller Cache Memory shutdown |
|
|
|
|
| operation as follows: 1 = Success 2 = Failure 3 = Not applicable The |
|
|
|
|
| old_attr.value.u32[1] field contains the internal Storage System Management |
|
|
|
|
| Interface cache shutdown status code. The old_attr.value.u32[2] field value |
|
|
|
|
| indicates the result of the Physical Disk Drive enclosure(s) power off operation as |
|
|
|
|
| follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[3] |
|
|
|
|
| field contains the internal Storage System Management Interface Physical Disk |
|
|
|
|
| Drive enclosure(s) power off status code. The old_attr.value.u32[4] field value |
|
|
|
|
| indicates the result of the battery assemblies disable operation as follows: 1 = |
|
|
|
|
| Success 2 = Failure 3 = Not applicable <P > The old_attr.value.u32[5] field value |
|
|
|
|
| indicates the battery assemblies disable operation failure mode as follows: 0 = |
|
|
|
|
| No failure indicated. 1 = Failed only on the HSV110 controller identified in the |
|
|
|
|
| handle field. 2 = Failed only on the other HSV110 controller of the pair. 3 = |
|
|
|
|
| Failed on both HSV110 controllers. |
|
|
|
|
|
|
2504 | 880309c8 | 6 | 9 | c8 | Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the |
|
|
|
|
| internal Logical Disk associated with the Virtual Disk identified in the handle field |
|
|
|
|
| has has transitioned to the DATA LOST state. The value.ul1 field contains the new |
|
|
|
|
| state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL). |
|
|
|
|
|
|
2505 | 880309c9 | 6 | 9 | c9 | Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group |
|
|
|
|
| identified in the handle field has transitioned to an INOPERATIVE state. The |
|
|
|
|
| value.ul1 field contains the new Disk Group state. The value.ul2 field contains the |
|
|
|
|
| old Disk Group state. The state values that may be found in the value.ul1 and |
|
|
|
|
| value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no redundancy |
|
|
|
|
| is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk |
|
|
|
|
| Group with mirrored redundancy is inoperative 5 = Disk Group with no |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
|
|
42 | Storage Management Appliance Software Event Code Definitions Application Notes |