HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. |
| Description |
ID | Code | erity | ID | No. |
| |
3419 | 88030d5b | 3 | d | 5b | Storage Cell: %1 | Event Code: %2 Description: A drive enclosure temperature |
|
|
|
|
| sensor out of range condition has been reported by one of the drive enclosure | |
|
|
|
|
| elements. This problem was detected by the Drive Enclosure Environmental | |
|
|
|
|
| Monitoring Unit located in the drive enclosure identified in the dencl_num field | |
|
|
|
|
| within the rack identified in the rack_num field. The rack_num field will not be | |
|
|
|
|
| valid until a future release. The location of the temperature sensor (1 through 11) | |
|
|
|
|
| is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1 | |
|
|
|
|
| Exhaust 2 = Power Supply 2 Exhaust 3 = Drive Enclosure Environmental | |
|
|
|
|
| Monitoring Unit 4 | = Drive Bay 1 5 = Drive Bay 2 6 = Drive Bay 3 7 = Drive |
|
|
|
|
| Bay 4 8 = Drive Bay 5 9 = Drive Bay 6 A = Drive Bay 7 B = Drive Bay 8 C = | |
|
|
|
|
| Drive Bay 9 D = Drive Bay 10 E = Drive Bay 11 F = Drive Bay 12 10 = Drive | |
|
|
|
|
| Bay 13 11 = Drive Bay 14 The temperature sensor out of range condition is | |
|
|
|
|
| described by the content of the alarm_error_code.fie ld.ec field as follows: 1 = | |
|
|
|
|
| The element temperature is approaching, but has not reached, the high | |
|
|
|
|
| temperature CRITICAL threshold. Continued operation under these conditions | |
|
|
|
|
| may result in a CRITICAL condition and may reduce an element’s MTBF. 2 = The | |
|
|
|
|
| element temperature is above the high temperature CRITICAL threshold. | |
|
|
|
|
| Continued operation under these conditions may result in element failure. 3 = | |
|
|
|
|
| The element temperature is approaching, but has not reached, the low | |
|
|
|
|
| temperature CRITICAL threshold. Continued operation under these conditions | |
|
|
|
|
| may result in a CRITICAL condition and may reduce an element’s MTBF. 4 = The | |
|
|
|
|
| element temperature has reached the low temperature CRITICAL threshold. | |
|
|
|
|
| Continued operation under these conditions may result in element failure. The | |
|
|
|
|
| actual temperature threshold values can be found in the HSV element manager | |
|
|
|
|
| GUI. |
|
|
|
|
|
|
|
|
3423 | 88030d5f | 6 | d | 5f | Storage Cell: %1 | Event Code: %2 Description: The average temperature of two |
|
|
|
|
| of the three temperature sensor groups (i.e., Drive Enclosure Environmental | |
|
|
|
|
| Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. | |
|
|
|
|
| The operational power supply(s) will automatically shut down after a short period | |
|
|
|
|
| of time, thereby disabling the drive enclosure. This condition remains active until | |
|
|
|
|
| either the problem is corrected, or the operational power supply(s) shut down, | |
|
|
|
|
| whichever occurs first. This problem was detected by the Drive Enclosure | |
|
|
|
|
| Environmental Monitoring Unit located in the drive enclosure identified in the | |
|
|
|
|
| dencl_num field within the rack identified in the rack_num field. The rack_num | |
|
|
|
|
| field will not be valid until a future release. Note that in this case the content of | |
|
|
|
|
| the alarm_error_code.field.en field is undefined. The actual temperature | |
|
|
|
|
| threshold values can be found in the HSV element manager GUI. | |
|
|
|
|
|
|
|
3439 | 88030d6f | 3 | d | 6f | Storage Cell: %1 | Event Code: %2 Description: An internal Drive Enclosure |
|
|
|
|
| Environmental Monitoring Unit error has occurred. This problem was detected by | |
|
|
|
|
| the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure | |
|
|
|
|
| identified in the dencl_num field within the rack identified in the rack_num field. | |
|
|
|
|
| The rack_num field will not be valid until a future release. The | |
|
|
|
|
| alarm_error_code.field.en field contains the value 1 signifying that the Drive | |
|
|
|
|
| Enclosure Environmental Monitoring Unit is the affected element. The cause of | |
|
|
|
|
| the improper operation is described by the content of the | |
|
|
|
|
| alarm_error_code.field.ec field as follows: 1 = An internal Drive Enclosure | |
|
|
|
|
| Environmental Monitoring Unit clock error has occurred. 2 = The | |
|
|
|
|
| bus is not processing data and the Drive Enclosure Environmental Monitoring | |
|
|
|
|
| Unit is unable to monitor or report the status of the elements or enclosures. 5 = A | |
|
|
|
|
| Backplane NVRAM error has occurred. | |
|
|
|
|
|
|
|