HSV Element Manager Event Codes

 

 

 

 

 

 

Table 8: HSV Element Manager Event Codes: Controller Events (Continued)

 

 

 

 

 

 

Event

Event

Sev-

SWC

Evt.

Description

ID

Code

erity

ID

No.

3509

88030db5

6

d

b5

Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply

 

 

 

 

 

current sensor out of range condition has been reported. This problem was

 

 

 

 

 

detected by the Drive Enclosure Environmental Monitoring Unit located in the

 

 

 

 

 

drive enclosure identified in the dencl_num field within the rack identified in the

 

 

 

 

 

rack_num field. The rack_num field will not be valid until a future release. The

 

 

 

 

 

location of the current sensor (1 through 4) is identified in the

 

 

 

 

 

alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =

 

 

 

 

 

Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12

 

 

 

 

 

VDC The current sensor out of range condition is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 1 = The element current is

 

 

 

 

 

approaching, but has not reached, the high current CRITICAL threshold.

 

 

 

 

 

Continued operation under these conditions may result in a CRITICAL condition.

 

 

 

 

 

2 = The element current is above the high current CRITICAL threshold.

 

 

 

 

 

 

3544

88030dd8

3

d

d8

Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane

 

 

 

 

 

invalid NVRAM read error has occurred. This problem was detected by the Drive

 

 

 

 

 

Enclosure Environmental Monitoring Unit located in the drive enclosure identified

 

 

 

 

 

in the dencl_num field within the rack identified in the rack_num field. The

 

 

 

 

 

rack_num field will not be valid until a future release. The

 

 

 

 

 

alarm_error_code.field.en field contains the value 1 signifying that the drive

 

 

 

 

 

enclosure is the affected element.

 

 

 

 

 

 

3545

88030dd9

6

d

d9

Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane

 

 

 

 

 

error has occurred. This problem was detected by the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit located in the drive enclosure identified in the

 

 

 

 

 

dencl_num field within the rack identified in the rack_num field. The rack_num

 

 

 

 

 

field will not be valid until a future release. The alarm_error_code.field.en field

 

 

 

 

 

contains the value 1 signifying that the drive enclosure is the affected element.

 

 

 

 

 

The cause of the improper operation is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 11 = Unable to write data to the

 

 

 

 

 

NVRAM. This problem prevents communication between elements in the

 

 

 

 

 

enclosure. 12 = Unable to read data from the NVRAM. This problem prevents

 

 

 

 

 

communication between elements in the enclosure. 13 = NVRAM has not been

 

 

 

 

 

initialized properly. This is a manufacturing error.

 

 

 

 

 

 

3549

88030ddd

6

d

dd

Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module

 

 

 

 

 

error has occurred. This problem was detected by the Drive Enclosure

 

 

 

 

 

Environmental Monitoring Unit located in the drive enclosure identified in the

 

 

 

 

 

dencl_num field within the rack identified in the rack_num field. The rack_num

 

 

 

 

 

field will not be valid until a future release. The location of the I/O module (A

 

 

 

 

 

(01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of

 

 

 

 

 

the improper operation is described by the content of the

 

 

 

 

 

alarm_error_code.field.ec field as follows: 1 = The I/O module’s Fibre Channel

 

 

 

 

 

link speed is not supported by the backplane. This error prevents the controller

 

 

 

 

 

from establishing a link with enclosure drives and eliminates the enclosure

 

 

 

 

 

dual-loop capability. 11 = Unable to write data to the I/O module NVRAM. 12

 

 

 

 

 

= Unable to read data from the I/O module NVRAM.

 

 

 

 

 

 

3550

88030dde

3

d

de

Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module is

 

 

 

 

 

unable to communicate with the Drive Enclosure Environmental Monitoring Unit.

 

 

 

 

 

This problem was detected by the Drive Enclosure Environmental Monitoring Unit

 

 

 

 

 

located in the drive enclosure identified in the dencl_num field within the rack

 

 

 

 

 

identified in the rack_num field. The rack_num field will not be valid until a future

 

 

 

 

 

release. The location of the I/O module (A (01) and B (02)) is identified in the

 

 

 

 

 

alarm_error_code.field.en field.

 

 

 

 

 

 