HP StorageWorks SAN and Brocade Switch Event Codes

HP StorageWorks SAN and Brocade Switch Event Codes

The following events are generated by HP StorageWorks SAN switches and Brocade switches and are recorded in the Storage Management Appliance Event Log. Many of these event types have several possible states and each state has an appropriate severity code.

The Storage Management Appliance supports the StorageWorks SAN and Brocade MIB version 4.0.

Table 6: StorageWorks SAN and Brocade Switch Event Codes

Event

Event

 

 

 

ID

Code

Possible States

Severity

Description

105

88020069

unknown

0

Port Index %2 changed state to %1%n

 

 

online

2

SSN: %3%n

 

 

offline

5

GroupName: %3%n

 

 

testing

2

GroupType: %5%n

 

 

faulty

7

Group MemPosition: %6%n

 

 

 

 

A swFCPortScn(3) is generated whenever

 

 

 

 

an FC_Port changes its operational state.

 

 

 

 

For instance, the FC_Port goes from on-line

 

 

 

 

to offline. The VarBind in the Trap Data Unit

 

 

 

 

shall contain the corresponding instance of

 

 

 

 

the FC_Port's operational status and index.

 

 

 

 

 

101

88020065

ok

2

Switch is faulty.

 

 

faulty

5

Faulty reason: %1%n

 

 

unknown

0

SSN: %2%n

 

 

 

 

GroupName: %3%n

 

 

 

 

GroupType: %4%n

 

 

 

 

Group MemPosition: %5%n

 

 

 

 

A swFault(1) is generated whenever the

 

 

 

 

diagnostics detects a fault with the switch.

 

 

 

 

 

103

88020067

unknown

0

%5 is currently in state %1%n

 

 

faulty

5

SSN: %7%n

 

 

below minimum

7

GroupName: %3%n

 

 

normal

2

GroupType: %8%n

 

 

above maximum

5

Group MemPosition: %9%n

 

 

absent

2

A swSensorScn(2) is generated whenever

 

 

 

 

an environment sensor changes its

 

 

 

 

operational state. For instance, a fan stops

 

 

 

 

working. The VarBind in the Trap Data Unit

 

 

 

 

shall contain the corresponding instance of

 

 

 

 

the sensor status, sensor index, sensor type,

 

 

 

 

sensor value (reading) and sensor

 

 

 

 

information. Note that the sensor

 

 

 

 

information contains the type of sensor and

 

 

 

 

its number in textual format.

 

 

 

 

 

107

8802006B

critical

5

Event %1: %2 (severity level %3) - %5%n

 

 

error

5

SSN: %6%n

 

 

warning

3

GroupName: %7%n

 

 

informational

2

GroupType: %8%n

 

 

debug

2

GroupMemPosition: %9%n

 

 

 

 

This trap is generated when an event whose

 

 

 

 

level at or below swEventTrapLevel occurs.

 

 

 

 

 

Storage Management Appliance Software Event Code Definitions Application Notes