HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event | Event | Sev- | SWC | Evt. |
| Description |
ID | Code | erity | ID | No. |
| |
3564 | 88030dec | 3 | d | ec | Storage Cell: %1 Event Code: %2 | Description: A drive enclosure I/O module |
|
|
|
|
| invalid NVRAM read error has occurred. This problem was detected by the Drive | |
|
|
|
|
| Enclosure Environmental Monitoring Unit located in the drive enclosure identified | |
|
|
|
|
| in the dencl_num field within the rack identified in the rack_num field. The | |
|
|
|
|
| rack_num field will not be valid until a future release. The location of the I/O | |
|
|
|
|
| module (A (01) or B (02)) is identified in the alarm_error_code.field.en field. | |
|
|
|
|
|
| |
3568 | 88030df0 | 2 | d | f0 | Storage Cell: %1 Event Code: %2 Description: The status has changed on one or | |
|
|
|
|
| more of the drive enclosures. This is an informational event triggered by the | |
|
|
|
|
| occurrence of a change in the status of a drive enclosure. The content of the | |
|
|
|
|
| alarm_error_code field, drive enclosure, and rack number have no meaning for | |
|
|
|
|
| this event. |
|
|
|
|
|
|
|
|
16896 | 88034200 | 2 | 42 | 0 | Storage Cell: %1 Event Code: %2 | Description: Indicated Host Fibre Channel |
|
|
|
|
| port transitioned to link down. |
|
|
|
|
|
|
|
|
16897 | 88034201 | 2 | 42 | 1 | Storage Cell: %1 Event Code: %2 | Description: Indicated Host Fibre Channel |
|
|
|
|
| port transitioned to link failed. |
|
|
|
|
|
|
|
|
16899 | 88034203 | 2 | 42 | 3 | Storage Cell: %1 Event Code: %2 | Description: An excessive number of link |
|
|
|
|
| errors were detected on a Fibre Channel port. The error counters are checked | |
|
|
|
|
| every hour. This is an informational event that reports all link status errors | |
|
|
|
|
| detected by the Tachyon chip, triggered by an excessive number detected in one | |
|
|
|
|
| category. |
|
|
|
|
|
|
|
|
16900 | 88034204 | 3 | 42 | 4 | Storage Cell: %1 Event Code: %2 | Description: A Fibre Channel port on the |
|
|
|
|
| HSV110 controller has failed to respond. The evt_peq.peb field contains port | |
|
|
|
|
| event information. The evt_peq.peq_frz_prod_index field contains the index to | |
|
|
|
|
| the port event block that points to when the Tachyon chip entered the frozen state. | |
|
|
|
|
| The evt_peq.peq_prod_index field contains the index to the next port event block. | |
|
|
|
|
| The evt_peq.peq_cons_index field contains the index to the next port event block | |
|
|
|
|
| to be acted upon. |
|
|
|
|
|
|
| |
33536 | 88038300 | 6 | 83 | 0 | Storage Cell: %1 Event Code: %2 Description: A failure was detected during the | |
|
|
|
|
| execution of this HSV110 controller’s on board diagnostics. | |
|
|
|
|
|
|
|
52 | Storage Management Appliance Software Event Code Definitions Application Notes |