| HSV Element Manager Event Codes |
|
|
|
|
|
|
Table 8: HSV Element Manager Event Codes: Controller Events (Continued) | |||||
|
|
|
|
|
|
Event | Event | Sev- | SWC | Evt. | Description |
ID | Code | erity | ID | No. | |
2506 | 880309ca | 6 | 9 | ca | Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical |
|
|
|
|
| Disk associated with the Virtual Disk identified in the handle field has transitioned |
|
|
|
|
| to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The |
|
|
|
|
| value.ul2 field contains the old state. The state values that may be found in the |
|
|
|
|
| value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 = |
|
|
|
|
| Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 6 = |
|
|
|
|
| Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8 |
|
|
|
|
| = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to |
|
|
|
|
| data lost |
|
|
|
|
|
|
2507 | 880309cb | 6 | 9 | cb | Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical |
|
|
|
|
| Disk associated with the Virtual Disk identified in the handle field has transitioned |
|
|
|
|
| to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new |
|
|
|
|
| state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state. |
|
|
|
|
| The state values that may be found in the value.ul2 field are as follows: 1 = |
|
|
|
|
| Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in |
|
|
|
|
| progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in progress |
|
|
|
|
| 8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due |
|
|
|
|
| to device data lost |
|
|
|
|
|
|
2508 | 880309cc | 6 | 9 | cc | Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical |
|
|
|
|
| Disk associated with the Virtual Disk identified in the handle field has transitioned |
|
|
|
|
| to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10 |
|
|
|
|
| (DEVICE DATA LOST). The value.ul2 field contains the old state. The state values |
|
|
|
|
| that may be found in the value.ul2 field are as follows: 1 = Normal 2 = |
|
|
|
|
| Replacement delay in progress 3 = Redundancy lost restore, in progress 4 = |
|
|
|
|
| Redundancy lost restore, stalled 5 = Failed 6 = Creation in progress 7 = |
|
|
|
|
| Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9 |
|
|
|
|
| = Capacity change in progress |
|
|
|
|
|
|
2509 | 880309cd | 6 | 9 | cd | Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel |
|
|
|
|
| port identified in the attribute.value.str field and located on the rear panel of the |
|
|
|
|
| HSV110 controller identified in the handle field has transitioned to the FAILED |
|
|
|
|
| state. The attribute.type field contains the value 4. The value.ul1 field contains |
|
|
|
|
| the new state: 2 (FAILED). The value.ul2 field contains the old state: 1 |
|
|
|
|
| (NORMAL). Note that the HSV110 controller’s internal identity of the affected |
|
|
|
|
| Fibre Channel port is contained in the secondary_id field. |
|
|
|
|
|
|
2510 | 880309ce | 2 | 9 | ce | Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group |
|
|
|
|
| identified in the handle field has transitioned to an INOPERATIVE MARKED state. |
|
|
|
|
| The value.ul1 field contains the new Disk Group state. The value.ul2 field |
|
|
|
|
| contains the old Disk Group state. The state values that may be found in the |
|
|
|
|
| value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no |
|
|
|
|
| redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative |
|
|
|
|
| 4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
| redundancy is inoperative, marked for |
|
|
|
|
|
|
2511 | 880309cf | 3 | 9 | cf | Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk |
|
|
|
|
| Drive identified in the handle field has transitioned to the NOT PRESENT state. |
|
|
|
|
| The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field |
|
|
|
|
| contains the old state. The state values that may be in the value.ul2 field are as |
|
|
|
|
| follows: 1 = Normal 2 = Degraded 3 = Failed |
|
|
|
|
|
|
2512 | 880309d0 | 2 | 9 | d0 | Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified |
|
|
|
|
| in the handle field no longer needs attention. |
|
|
|
|
|
|
Storage Management Appliance Software Event Code Definitions Application Notes | 43 |