kug-appb Page 5 Thursday, March 6, 1997 4:50 PM

R e p l a c i n g C o n s u m a b l e s

Replacingthe FuserCartridge/BTR

The fuser area is extremely hot. Turn the printer OFF and allow it to cool for 40 minutes before replacing an existing

fuser cartridge.

Caution • Replacing the BTR (Bias Transfer Roll) requires removing the EP cartridge. Do not expose the EP cartridge to direct sunlight or artificial light for more than 15 minutes. Overexposure will permanently damage the photosensitive imaging drum.

1 Power OFF the printer and disconnect the power cord and any interface cables.

40

2 Open the rear cover.

3 Let the fuser area cool for 40 minutes.

 

If the Duplex Module is installed, continue

 

with Step 4 on page B-6. Otherwise, skip

 

to Step 5 on page B-6.

A p p e n d i x B : R e p l a c i n g C o n s u m a b l e s B-5