19.Add comments for the serviceable event. Include any unique additional information. Click OK. The following steps will add or update FRU information.
20.Did you replace, add, or modify a FRU of the open service action event?
vYes: Continue with the next step.
vNo: Go to step 22.
21.From the FRU list, select a FRU that you need to update.
22.Select the No FRU Replaced for this Serviceable Event option.
23.Click OK to close the service action event.
24.Is the list of all partitions you recorded in step 11 on page 82 empty?
vYes: Go to step 32 on page 84.
vNo: Continue with the next step.
25.Does the list of all partitions you recorded in step 11 on page 82 contain more than one entry?
vYes: Continue with the next step.
vNo: Go to step 32 on page 84.
26.Is the error class recorded in step 25 AIX?
vYes: Continue with the next step.
vNo: Go to step 32 on page 84.
27.Perform the following steps for each entry in the list of all partitions you recorded in step 11 on page 82, except the partition you were using to debug the original problem.
28.From the HMC virtual terminal window of a partition in the list of all partitions, type diag at the AIX command prompt.
29.When the diagnostic operating instructions are displayed, do the following steps: