Activating or deactivating an identify LED using the Advanced System Management Interface

You can activate or deactivate an identify LED using the Advanced System Management Interface (ASMI).

You can specify the location code of any indicator to view or modify its current state. If you provide the wrong location code, the advanced system manager attempts to go to the next higher level of the location code.

The next level is the base-level location code for that field replaceable unit (FRU). For example, a user types the location code for the FRU located on the second I/O slot of the third enclosure in the system. If the location code for the second I/O slot is incorrect (the FRU does not exist at this location), an attempt to set the indicator for the third enclosure is initiated. This process continues until a FRU is located or no other level is available.

To perform this operation, your authority level must be one of the following levels:

vAdministrator

vAuthorized service provider

To change the current state of an indicator, do the following steps:

1.On the ASMI Welcome pane, specify your user ID and password, and click Log In.

2.In the navigation area, expand System Configuration Service Indicators Indicators by Location code.

3.In the right pane, enter the location code of the FRU and click Continue.

4.Select the preferred state from the list.

5.Click Save settings.