Action

Contact IBM technical support for assistance.

CMUN02375E SOURCE Volume group operation failure

Explanation

The storage management console server reports a storage unit microcode-level error.

Action

Contact IBM technical support for assistance.

CMUN02376E SOURCE Unable to modify logical volume: invalid data type

Explanation

The logical volume cannot be modified because the specification contains an invalid data type.

Action

Specify a valid data type, and the resubmit the task.

CMUN02377E SOURCE Error: inconsistent alias and base logical volume numbers

Explanation

The first two digits of an alias logical volume number and its base logical volume number must be identical.

Action

Specify consistent alias and base logical volume numbers, and then resubmit the task.

CMUN02378E SOURCE Error: A volume of this type cannot have an alias volume group.

Explanation

An alias volume group is specified for a volume type that does not support the specification of aliases.

Action

Correct the specification, and then resubmit the task.

234IBM TotalStorage DS8000: Messages Reference

Page 254
Image 254
IBM DS8000 manual CMUN02375E Source Volume group operation failure