IBM DS8000 manual File Filename

Models: DS8000

1 374
Download 374 pages 22.96 Kb
Page 58
Image 58

CMUC00110E COMMAND_INFO No matching candidate connection found.

Explanation

The candidate Remote Mirror and Copy path between source and target ports cannot be established because one or both of the physical connections cannot be found.

Action

Specify existing source and target ports, and then resubmit the command.

Tip: Enter help command_namefor more information.

CMUC00111E COMMAND_INFO One or more of the specified volumes is not within the specified LSS.

Explanation

This command requires a logical subsystem ID and one or more volume IDs. The volumes must be members of the specified logical subsystem. One or more of the volumes are not members of the specified logical subsystem.

Action

Specify only volumes within the specified logical subsystem, and then resubmit the command.

CMUC00112E COMMAND_INFO Port candidate VALUE_0 is not available for an ESCON connection.

Explanation

You are attempting to create a path between source and target logical subsystems on an IBM model 2105 storage unit over an ESCON connection. The specified port is not available for an ESCON connection. This might be because the port does not exist, because it is not identified as an ESCON port, or because it is already in use.

Action

Use the lsavailpprcport command to list available ports and their types. Specify an available ESCON port, and then resubmit the command.

CMUC00113E COMMAND_INFO Record VALUE_1 already exists in password

file FILE_NAME.

Explanation

You are attempting to add a password record in the password file. However, the specified user name already exists in the file.

38IBM TotalStorage DS8000: Messages Reference