IBM DS8000 manual Specify the correct primary, and then resubmit the task

Models: DS8000

1 374
Download 374 pages 22.96 Kb
Page 295
Image 295

vA start or resume Global Mirror command with no modify options is being issued to a storage image on which a master process is running.

vA start or resume Global Mirror command with modify options is being issued, but the parameters do not match the existing configuration.

vA start or resume Global Mirror command with modify options is being issued, but the master process is not paused.

Action

Ensure that the master process is not running and that the parameters match.

Resubmit the task.

CMUN03029E SOURCE Copy Services operation failure: invalid failback primary

Explanation

The specified failback primary does not match the existing primary for the volume.

Action

Specify the correct primary, and then resubmit the task.

CMUN03030E SOURCE Copy Services operation failure: failback primary volume not suspended

Explanation

The Remote Mirror and Copy failback primary volume must be suspended before the task is issued.

Action

Suspend the failback primary volume, and then resubmit the task.

CMUN03031E SOURCE Copy Services operation failure: invalid failover primary site

Explanation

The specified failover primary site does not match the existing primary site for the volume.

Action

Specify the correct failover primary site, and then resubmit the task.

Chapter 7. DS storage management console server messages 275

Page 295
Image 295
IBM DS8000 manual Specify the correct primary, and then resubmit the task