Tip: Enter help command_name for more information.
CMUC00107E COMMAND_INFO The parameter value VALUE_0 is smaller
than the minimum allowable value: VALUE_1.
Explanation
The parameter that has been supplied is smaller than the minimum value that is
allowed.
Action
Specify a value equal to or higher than the minimum value that is allowed, and then
resubmit the command.
Tip: Enter help command_name for more information.
CMUC00108E COMMAND_INFO The Remote Mirror and Copy volume pair
must be in full-duplex mode before the host server can read from
target volumes.
Explanation
The No Target Read -notgthread option has been specified, and the pair is not in
full-duplex mode. For the host server to read the volume, the Remote Mirror and
Copy volume pair must be in full-duplex mode.
Action
Place the pair in full-duplex mode, and then resubmit the command. You can use
the -mode full option to place the Remote Mirror and Copy volume pair in
full-duplex mode.
Tip: Enter help command_name for more information.
CMUC00109E COMMAND_INFO The -uconditional flag is invalid unless
it is used in conjunction with the -at parameter.
Explanation
The -uconditional flag indicates that a source or target volume has been selected
individually, and not as a pair. It is valid only if the -at option specifies a source or a
target.
Action
Specify both -uconditional and -at flags, and then resubmit the command.
Tip: Enter help command_name for more information.
Chapter 2. DS command-line interface messages 37