CMUC00107E COMMAND_INFO The parameter value VALUE_0 is smaller than the minimum allowable value: VALUE_1.

Explanation

The parameter that has been supplied is smaller than the minimum value that is allowed.

Action

Specify a value equal to or higher than the minimum value that is allowed, and then resubmit the command.

Tip: Enter help command_namefor more information.

CMUC00108E COMMAND_INFO The Remote Mirror and Copy volume pair must be in full-duplex mode before the host server can read from target volumes.

Explanation

The No Target Read -notgthreadoption has been specified, and the pair is not in full-duplex mode. For the host server to read the volume, the Remote Mirror and Copy volume pair must be in full-duplex mode.

Action

Place the pair in full-duplex mode, and then resubmit the command. You can use the -mode full option to place the Remote Mirror and Copy volume pair in full-duplex mode.

Tip: Enter help command_namefor more information.

CMUC00109E COMMAND_INFO The -uconditional flag is invalid unless it is used in conjunction with the -at parameter.

Explanation

The -uconditionalflag indicates that a source or target volume has been selected individually, and not as a pair. It is valid only if the -atoption specifies a source or a target.

Action

Specify both -uconditionaland -atflags, and then resubmit the command.

Tip: Enter help command_namefor more information.