CMUN03012E SOURCE Remote Mirror and Copy operation failure

Explanation

The storage management console server reports a Remote Mirror and Copy error. One of the following conditions is occurring:

vAbnormal conditions exist at the secondary controller.

vAbnormal conditions exist at the secondary storage unit.

vThe communication paths between the primary and remote controller are not functioning.

vCommunication cannot be established with the secondary control unit.

Action

Check for hardware errors and disconnected cables, and follow the recommended service procedure. Check the status of the secondary system. If the problem persists, contact IBM technical support for assistance.

CMUN03013E SOURCE CKD management is disabled.

Explanation

Management of count-key-data resources on the storage unit is disabled.

Action

Contact IBM technical support for assistance.

CMUN03014E SOURCE Copy Services operation failure: A microcode code load is in progress.

Explanation

A microcode code load is in progress, and no other activities can take place on the storage unit.

Action

Wait until the microcode code load completes, and then resubmit the task.

CMUN03015E SOURCE Operation failure: consistent copy would be compromised

Explanation

A pause or end Global Mirror fails because the action cannot complete without compromising the consistent copy of the data.

Action

Contact IBM technical support for assistance.

Chapter 7. DS storage management console server messages 271

Page 291
Image 291
IBM DS8000 manual CMUN03012E Source Remote Mirror and Copy operation failure, CMUN03013E Source CKD management is disabled