CMUN02023E SOURCE Unable to modify logical subsystem: cannot set session timeout

Explanation

The specified session timeout value is negative. Only positive values are valid.

Action

Specify a valid timeout value, and then resubmit the task.

CMUN02024E SOURCE Unable to modify logical subsystem: invalid critical mode enabled

Explanation

The specification contains an invalid value for the critical mode enabled parameter.

Action

Specify a valid value, and then resubmit the task. If the problem persists, contact IBM technical support for assistance.

CMUN02025E SOURCE Unable to modify logical subsystem: invalid extended long busy enabled

Explanation

The specification contains an invalid value for the extended long busy enabled parameter.

Action

Specify a valid value, and then resubmit the task. If the problem persists, contact IBM technical support for assistance.

CMUN02026E SOURCE Unable to modify logical subsystem: invalid extended long busy time

Explanation

The specified extended long busy time value is negative. Only positive values are valid.

Action

Specify a valid value, and then resubmit the task. If the problem persists, contact IBM technical support for assistance.

156IBM TotalStorage DS8000: Messages Reference