CMUN03075E SOURCE Copy Services operation failure: path timeout

Explanation

The storage management console server reports a Copy Services error.

Communication to the secondary timed out.

Action

Contact IBM technical support for assistance.

CMUN03076E SOURCE Operation failure: path type mismatch

Explanation

ESCON and FCP paths cannot be established over the same hardware. A path of the other type already exists.

Action

Contact IBM technical support for assistance.

CMUN03077E SOURCE Copy Services operation failure: pinned data

Explanation

A Remote Mirror and Copy establish pair action is being issued against a logical volume that is suspended with pinned data. A relationship cannot be established using a suspended logical volume that has pinned data.

Action

Consider carefully before you discard pinned data. You might want to specify a different logical volume. Place both logical volumes in the simplex state, and then resubmit the task.

CMUN03078E SOURCE Copy Services operation failure: pinned data

Explanation

A Remote Mirror and Copy or FlashCopy pair action is being issued against a logical volume that has pinned data. A relationship cannot be established using a logical volume with pinned data.

Action

Consider carefully before you discard pinned data. You might want to specify a different logical volume. Place both logical volumes in the simplex state, and then resubmit the task.

286IBM TotalStorage DS8000: Messages Reference

Page 306
Image 306
IBM DS8000 manual CMUN03076E Source Operation failure path type mismatch