CMUC00169I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully reversed.

Explanation

The original FlashCopy source volume has been made the target volume. The original FlashCopy target volume has been made the source volume. Any uncommitted incremental changes to the original source volume data have been overwritten with older data from the new source volume.

Action

None.

CMUC00170I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully committed.

Explanation

Changes to the FlashCopy source volume data have been committed to the target volume.

Action

None.

CMUC00171I COMMAND_INFO FlashCopy volume pair PAIR_ID successfully reverted.

Explanation

All new writes to the source volume since the last time source data was committed to the target volume have been discarded.

Action

None.

CMUC00172I COMMAND_INFO FlashCopy consistency group for logical subsystem PAIR_ID successfully reset.

Explanation

A mkflash -freezeor resyncflash -freezecommand has been invoked previously against this consistency group. The unfreezeflash command successfully reset the consistency group.

Action

None.

52IBM TotalStorage DS8000: Messages Reference