IBM MaxLoader manual Config Option / Auto Inc, File Save

Models: MaxLoader

1 118
Download 118 pages 6.46 Kb
Page 91
Image 91
File Save

MaxLoader User’s Guide

-File Offset is subtracted from addresses from the file downloaded to the programmer. For example, if you set File Offset to 1000h, then the downloaded data minus 1000h would be placed into the buffer at the address specified by the Buffer Start Address.

-Buffer Start Address is the address in the buffer where you want your downloaded data to start. For example, if you set Buffer Start Address to 800h, then the downloaded data only appears in the buffer beginning at address 800h.

File Save

These addresses will be applied for programming the buffer data. -Buffer Start: Starting address for data to be saved.

-Buffer End: Ending address for data to be saved.

Config Option / Auto Inc

The feature allows users to program a certain area that might contain a serial number in the memory device with serialized number by a certain value.

Start: Start address of memory that contains serialized data

End: End address of memory

91

Page 91
Image 91
IBM MaxLoader manual Config Option / Auto Inc, File Save