IBM QMS 4525 Space Requirements, Room Ventilation, Room Volume, Acoustic Noise Emission, Depth

Models: QMS 4525

1 180
Download 180 pages 12.33 Kb
Page 139
Image 139
Depth

Physical

Specifications

With buffers 57.7" (1465 mm)

Depth

Without buffers 29.0" (735 mm)

With buffers 30.3" (770 mm)

Space Requirements

For operator: 24" (600 mm) at the front, on the right-hand and the left-hand side

For service: 24" (600 mm) on all sides

Angle of inclination: Maximum of 4°

Room Ventilation

Recommended: Minimum of 438 cubic feet/hour (12.5 m3/h)

Room Volume

Recommended: Minimum of 855 cubic feet (25 m3)

With this room volume and the recommended room ventilation the ozone emission is within the Threshold Limited Value for ozone (0.2 mg/m3).

2&DXWLRQ￿￿)RU￿UHPRYDO￿RI￿KHDW￿￿H[WUD￿YHQWLODWLRQ￿PD\￿EH￿QHFHVVDU\￿

Acoustic Noise Emission

Stand-by: maximum 47 db (A)

Printing: maximum 64 db (A)

Impulse: maximum 73 db (A)

2&DXWLRQ￿￿8VH￿RI￿FRQWUROV￿RU￿DGMXVWPHQWV￿RU￿SHUIRUPDQFH￿RI￿SURFHGXUHV￿RWKHU￿ WKDQ￿WKRVH￿VSHFLILHG￿KHUHLQ￿PD\￿UHVXOW￿LQ￿KD]DUGRXV￿UDGLDWLRQ￿H[SRVXUH￿