Collating Output
stacker/stapler. The illustration below shows the collated and uncol- lated stacking for two copies of a
Collated | Uncollated |
|
The system administrator chooses the default collation setting for all print jobs via the Configuration menu. (See the system administrator's guide for additional information.) The default collation setting is used when collation is not specified first by the emulation (application or printer language), or next by the DOC collate command (this includes the network print commands). Some emulations are capable of speci- fying collation through language specific mechanisms such as the setcollate statusdict operators for level 1 or level 2. (See the system administrator's guide for information on this operator).
Using QMS DOC
The QMS DOC command syntax to set collation is
%%IncludeFeature: collate (selection)
Your choices for selection are on and off. (See the QMS Crown Docu- ment Option Commands manual for complete information.) This over- rides the Operator Control/Collation setting. Collation is set by the first subjob in a session and applies to all subsequent subjobs in the ses- sion unless explicitly reset by the option within the subjob. (See the
Printing Your Files |