IBM T400F Diagnostic and maintenance functions continued, Running a Fibre Channel Wrap Test

Models: T400F T400

1 136
Download 136 pages 49.86 Kb
Page 52
Image 52
Running a Fibre Channel Wrap Test

Table 9. Diagnostic and maintenance functions (continued)

Running a Fibre Channel Wrap Test

This test evaluates the Fibre Channel circuitry at the drive’s Fibre Channel connector, then at the fiber cable. A Fibre Channel wrap plug is required for this procedure. To run the wrap test through the fiber cable, a duplex adapter is required.

All cables and wrap plugs are hot-pluggable (that is, they can be removed from or added to the drive while the drive or its enclosure is powered-on). Do not bend the fiber cable more than a radius of 50.8 mm (2 in.) or the optical fiber may break.

1.Take all devices on the Fibre Channel offline (for instructions, refer to your server’s documentation).

2.Make sure that no cartridge is in the drive.

3.Disconnect the fiber cable from the drive and replace it with the Fibre Channel wrap plug. (When you disconnect the cable, the connection to the Fibre Channel loop may break, but will be restored at the end of the procedure when you reconnect the cable. For other devices on the loop, operations may temporarily be disrupted.)

Attention: Do not run the wrap test while the drive is connected to a Fibre Channel loop. This could disturb the Fibre Channel loop and cause performance or I/O problems.

4.Within a 1.5-second interval, press the unload button three times. The status light becomes solid amber, which means that the drive is in maintenance mode.

Note: If a cartridge is in the drive, it will eject the first time that you press the unload button and the drive will not be placed in maintenance mode. To continue placing the drive in maintenance mode, remove the cartridge and repeat this step.

5.Press the unload button once per 1.5 seconds until 6 appears in the single-character display. Note: If you cycle past 6, press the unload button once per second until it redisplays.

Testing the Circuitry at the Drive’s Fibre Channel Connector

6.To select the function, press and hold the unload button for 3 seconds. After you select the function, the tape drive automatically starts the test:

v If the test is successful, the circuitry at the drive’s Fibre Channel connector is working properly. The test loops and begins again. Press the unload button. 0 displays and the tape drive exits maintenance mode. Continue to step 7 to test the fiber cable.

vIf the test fails, an error code displays and the status light flashes amber. The test stops and the drive exits maintenance mode. To resolve the error, locate the code in Table 15 on page 67.

7.Disconnect the Fibre Channel wrap plug from the drive.

Testing the Circuitry at the Fiber Cable

8.Connect the duplex adapter, then the Fibre Channel wrap plug to the end of the fiber cable. Note: The Fibre Channel wrap test can only be run on cable lengths up to 250 meters (820 ft).

9.Within a 1.5-second interval, press the unload button three times. The status light becomes solid amber, which means that the drive is in maintenance mode.

Note: If a cartridge is in the drive, it will eject the first time that you press the unload button and the drive will not be placed in maintenance mode. To continue placing the drive in maintenance mode, remove the cartridge and repeat this step.

10.Press the unload button once per 1.5 seconds until 6 appears in the single-character display. Note: If you cycle past 6, press the unload button once per second until it redisplays.

11.To select the function, press and hold the unload button for 3 seconds. After you select the function, the tape drive automatically starts the test:

vIf the test is successful, the drive and the cable are working properly. The problem is at the server. To resolve the error, refer to the service guide for the server.

vIf the test fails, replace the fiber cable.

12.Remove the Fibre Channel wrap plug and the duplex adapter, and reconnect the fiber cable.

40IBM TotalStorage LTO Ultrium 2 Tape Drive

Page 52
Image 52
IBM T400F manual Diagnostic and maintenance functions continued, Running a Fibre Channel Wrap Test