DeviceNet to PLCs or Devices

Use Output Word xx

If you want to map this word of Output data to a PLC/Device register, select this option. If this option is not selected, any data appearing in this Output word will be ignored.

PLC/Device Address

This is the Address of the PLC/Device mapped to this word of Output data. The PLC/Device Address must be in the range 0 to 255.

File Number (Allen-Bradley PLCs only)

This is the File Number of the register in the PLC mapped to this word of Output data.

Register Number

This is the Register Number of the PLC/Device mapped to this word of Output data. Whenever the value in this Output word changes, the DN-3000 will write that value to the register specified by the PLC/Device Address, File Number and Register Number.