Intelligent Motion Systems MDrive34Plus manual Recommended Power and Cable Configurations

Models: MDrive34Plus

1 98
Download 98 pages 23.34 Kb
Page 38
Image 38
Recommended Power and Cable Configurations

Recommended Power and Cable Configurations

Cable length, wire gauge and power conditioning devices play a major role in the performance of your MDrive.

Example A demonstrates the recommended cable configuration for DC power supply cabling under 50 feet long. If cabling of 50 feet or longer is required, the additional length may be gained by adding an AC power supply cable (see Examples B & C).

Correct AWG wire size is determined by the current requirement plus cable length. Please see the MDrive Sup- ply Cable AWG Table at the end of this Appendix.

Example A – Cabling Under 50 Feet, DC Power

DC Voltage from

Power Supply

500 µf

+

Per Amp

-

Cable Length

Example A – Cabling Under 50 Feet, DC Power less than 50 Feet Manual background

πType RFI Filter

Required Current

Manual background To-MDrive

+

Shield to Earth Ground

Shielded Twisted Pair

Ferrite

on Supply End Only

(Wire Size from

Beads

 

MDrive Supply Cable AWG Table)

 

Figure 2.2.3: DC Cabling - Under 50 Feet

Example B – Cabling 50 Feet or Greater, AC Power to Full Wave Bridge

Transformer - 10 to 28 VAC RMS for 48 VDC Systems

20 to 48 VAC RMS for 75 VDC Systems

π Type RFI Filter

Shielded Twisted Pair

Required Current

(Wire Size from

 

 

MDrive Supply Cable AWG Table)

 

 

 

 

 

 

Shield to Earth Ground

 

Cable Length

on Supply End Only

 

 

 

as required

NOTE:

Connect the cable illustrated in Example A to the output of the Full Wave Bridge

+

To Cable A

-

Full Wave Bridge

Figure 2.2.4: DC Cabling - 50 Feet or Greater - AC To Full Wave Bridge Rectifier

Example C – Cabling 50 Feet or Greater, AC Power to Power Supply

 

 

NOTE:

 

 

π Type RFI Filter

 

Connect the cable illustrated

Shielded Twisted Pair

in Example A to the output of

Required Current

the Power Supply

 

 

(Wire Size from

 

DC Volts Out

 

MDrive Supply Cable AWG Table)

120 or 240 VAC

 

 

+

To Cable A

Dependent on

 

 

-

Power Supply

 

 

 

Shield to Earth Ground

Cable Length

 

 

 

on Supply End Only

 

 

 

 

as required

 

 

 

 

 

 

Power Supply

Figure 2.2.5: AC Cabling - 50 Feet or Greater - AC To Power Supply

2-10

MDrive 34Plus Microstepping Hardware - Revision R071108

 

Relevant to Firmware Version 3.0.02

Page 38
Image 38
Intelligent Motion Systems MDrive34Plus manual Recommended Power and Cable Configurations