Intelligent Motion Systems MDrive34Plus IMS Part Number/Serial Number Screen, Fault Indication

Models: MDrive34Plus

1 98
Download 98 pages 23.34 Kb
Page 59
Image 59
IMS Part Number/Serial Number Screen

IMS Part Number/Serial Number Screen

The IMS Part Number and Serial Number screen is accessed by clicking "View > Part and Serial Numbers".

This screen is read-only and will display the part and serial number, as well as the fault code if existing. IMS may require this information if calling the factory for support.

IMS Part #

IMS Serial Number

Figure 2.5.9: SPI Motor Interface Part and Serial Number Screen

Fault Indication

All of the IMS SPI Motor Interface Screens have the Fault field visible. This read-only field will display a 2 charac- ter error code to indicate the type of fault. The table below shows the error codes.

MDrive34Plus Microstepping Fault Codes

Binary

Error

Description

Action

To Clear

Case*

Code

 

 

 

None

No Fault

4

CS

SPI Checksum Error

Error

Write to MDM

Displayed

(Set Button)

 

 

 

8

SC/CS

SPI Checksum Error/

Error

Write to MDM

Sector Changing

Displayed

(Set Button)

 

 

16

DFLT

Defaults Checksum

Error

Write to MDM

Error

Displayed

(Set Button)

 

 

32

DATA

Settings Checksum

Error

Write to MDM

Error

Displayed

(Set Button)

 

 

64

TW

Temperature Warning

Error

Write to MDM

Displayed

(Set Button)

 

 

 

*All Fault Codes are OR'ed together

Table 2.5.4: MDrivePlus Microstepping Fault Codes

Part 2: Interfacing and Configuring

2-31

Page 59
Image 59
Intelligent Motion Systems MDrive34Plus manual IMS Part Number/Serial Number Screen, Fault Indication