Mounting MCS-3000X Expander to Controller
Important: Make All Connections with the Power Off. Turn the power off of all
Plan Work Area
You will want to work at a spacious, well lit surface. Spread a cloth on the surface to avoid scratching units.
Remove Top of
Remove Top of
Remove the six top panel screws of the Controller.
Lift top panel, a little forward and up. Invert and lay control- side down on a soft surface. (Circuit side up.)
Move Left End Bell
Remove the two screws that secure Controller's left end bell. (These screws will be tight). Attach the left end bell to the left side of the Expander.
Connect Controller to Expander with Plates Provided Place the Expander to the left of the Controller, side by side. Attach the thicker plate to the bottom of both units.
Lay thin (spring steel) plate on top of both units.
Replace top panels of the Controller, guiding in the Time Code jack and the LCD Contrast control into their holes. Replace the top panel of the Expander. Replace top screws. Replace Controller bottom screw. Replace any optional Cards in their card slots.