Operating/Maintenance Tips
CHANGING THE POWER NOZZLE BELT (cont)Make sure the Brash Roll Bristle Height Adjustment
5 setting (1, 2, or 3) is the same on both ends as when the brush was removed. See below for discussion of the
Brush Roll Bristle Height Adjustment (1, 2, or 3). Place the belt and Brush Roll back into the nozzle. One of the plastic Brush Roll ends is larger than the other, thus the Brush Roll will only fit in the nozzle one way.
Then center the belt on the Brush. >
Replace the Rug Plate by placing it on the front of the
6 bumper first and then pulling it over the bumper on the rear of the Power Nozzle (25). Secure the Rug Plate using the two latches that hold it in place. >
Using the handle on the Belt Lifter (20), turn it to the
7 left
Now you are ready to
The Brush Roll bristles wear away after long periods of use.
This reduces cleaning efficiency.
However, the ends of the Brush Roll are adjustable, so you can extend the bristles, allowing the brush to work like new again.
The Brush Roll on a new Sentria™ system has three settings: one notch, two notches and three notches. The greater the number of notches, the farther the bristles are extended. Use the one notch (1) setting for delicate carpeting such as berber. Use the
56